• Model:ACOAS-ADS-VFC

ACOAS-ADS-VFC - Automatic Duty Share Changeover panel

£ 143.00 (excl. VAT)

£ 171.60 (inc. VAT)

The ACOAS changeover panels are designed to suit single phase twin fan units with airflow switches. Please note that an airflow switch must be fitted to monitor each fan and the airflow switches must not “see” the airflow from the other fan I.E. the 2 airflow switches cannot be in the same airstream.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have fail contacts that can be used in conjunction with a remote indicator or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x Elta 10 Amp Electronic single phase speed controller.1 x NKS-D swirl diffuser v-300 x 300mm1 x Circular Ceiling Diffuser - TST 2001 x Circular Ceiling Diffuser - TST 1001 x PCA Diffuser - PCA-3151 x ELTA - Single Phase Transformer 2amps1 x Circular Ceiling Diffuser - TST 1251 x EC6H - Reversible Group Fan Electronic Controller1 x Round ceiling diffuser 400mm1 x Balance S Diffuser - NO RING - 125mm4 x Electronic extractor fan speed controller - FSC 1.51 x Elta 2 Amp Electronic single phase speed controller.1 x Circular Ceiling Diffuser - TST 1601 x JSR 200 Painted RAL50181 x Curved Blade Grille 600x600 (2way blow)1 x Elta 3 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 8amps1 x ELTA - Single Phase Transformer 16amps1 x Versio Square Ceiling Diffusers - RS141 x Elta 3 Amp Electronic single phase speed controller with TK1 x EFSC-3N- Single Phase Speed Control1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x Round ceiling diffuser 300mm1 x ELTA - Single Phase Transformer 4amps1 x ELTA - Single Phase Transformer 12amps1 x Round ceiling diffuser 200mm1 x Elta Variable Speed Drive IP66 - 0.75KW (1ph to 3ph)1 x EFSC-6N- Single Phase Speed Control3 x COM-31 x Round ceiling diffuser 250mm1 x PCA Diffuser - PCA-2501 x ELTA - Single Phase Transformer 10amps1 x Elta Variable Speed Drive IP66 - 1.5KW (1ph to 3ph)1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Helios ZNE Electronic Fan Overrun Timer1 x Time Delay Unit - DT20B2 x Multi Input Run On Timer - 0 - 20min - CFCU2 x Push Timer Switch - ZA41 x 7 Day Programmable TIMECLOCK1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x Vent Axia ACM 150 inline mixed flow duct fan1 x Three Phase Transformer controllers - RMT 1.5 Amp1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Isolator Switch - ISOSW1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel1 x CS2 Current Switch2 x MWS 1.5 – Transformer Controller With Motor Protection1 x Elta ACO Panel 149-ACO18B1 x EM30-24 Control Panel Commissioning Service1 x Transformer Speed Control - RTRE- 12.0Amp1 x WS - Reversing Switch from Helios Fans1 x Transformer (silent) speed controller - RE 3.0 Amp2 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x Helios HQW-630/4 - IP551 x TG-K3/NTC10-01 - Duct temperature sensor1 x Jetflow Silent SJMF-S 150-1EC1 x Envirovent G4 Filter - SL-G4/F71 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS
BD9/9 centrifugal M4 0.35Kw
BD9/9 centrifugal M4 0.35Kw
£ 399.00 now £ 350.00
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...