• Model:ACOFR9A-ADS-VFC

ACOFR9A-ADS-VFC - Automatic Duty Share Changeover panel

£ 139.00 (excl. VAT)

£ 166.80 (inc. VAT)

The ACOFR changeover panels are designed to suit single phase twin fan units where airflow switches are not fitted.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have run and fail contacts that can be used in conjunction with remote indicators or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x 204x60mm 90 Degree Vertical Bend1 x 204x60mm 45 Degree Vertical Bend1 x Elta SCP560/4-1AC - IP551 x Elta SLC630/4B-3AC - IP551 x ELTA - Single Phase Transformer 8amps1 x Spiral Duct Grille Termination - 630mm1 x CBT-80N Centrifugal ATEX II 2G Exe II T31 x GB-WSD 250 Weather Protection hood for the Giga-Box Fans - 250mm1 x CVAT/4-4000/400 ND 0.37Kw (230/400V50HZ) EXDIIBHT4 - ATEX RATED CABINET FAN1 x GB-WSD 355 Weather Protection hood for the Giga-Box Fans - 355mm1 x Soler & Palau TCBB/4-450/H - IP651 x SPI-315 C Iris damper1 x Soler & Palau - HCBT/4-1000/H-X - IP551 x HVWC800 WALL COWL - for use with the HV-800 belt driven fans1 x GB-WSG 630 External Weather Louvers for the Giga-Box Fans - 630mm1 x CBT-130N Centrifugal ATEX II 2G Exd IIB T41 x TUNE-R-200-3-M0 - Control Damper (NO ACTUATOR)1 x CTI CVA-N 450 Outdoor cover for CVAB/T Fans1 x Rosenberg ATEX DKHM 355-4SW.110.5DF-E751 x EX 140A-2 (Three Phase) Centrifugal Fan (ATEX)1 x Duct Termination with Mesh - 355mm1 x Ducting 30 Degree Bend - 150mm1 x SPI-150 C Iris damper1 x TUNE-R-250-3-M0 - Control Damper (NO ACTUATOR)1 x HV Wall Mounted Belt Drive Fan 1250mm 400V / 50Hz 1.1kW - Three Phase1 x Etaline 200mm1 x Commercial Activated Carbon Filters - Panel Type - 18" x 18" x 1 - ACP1 x WSD 042 (730x730x70)1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x KV 200 L Sileo1 x BDS 200/250 RA b/d shutter1 x RVK-EX 315D4 (ATEX) - 315mm Atex Rated Centrifugal Fan1 x OBD 450x450 - for use with 4WAY-5951 x Metal Inline Fan - VENT-200NK1 x GB-WSD 400 Weather Protection hood for the Giga-Box Fans - 400mm1 x CVAT Acoustic Kitchen Fan & Inverter Kit - CVAT/4-12000/560 ND - Pack 81 x Transformer (silent) speed controller - RE 1.5 Amp1 x U42K Screws for duct