• Model:ACOFR9A-ADS-VFC

ACOFR9A-ADS-VFC - Automatic Duty Share Changeover panel

£ 139.00 (excl. VAT)

£ 166.80 (inc. VAT)

The ACOFR changeover panels are designed to suit single phase twin fan units where airflow switches are not fitted.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have run and fail contacts that can be used in conjunction with remote indicators or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x BDB 400 TM - High Pressure Centrifugal Fan1 x DDMP 10-10 FLANGE1 x Ducting 30 Degree Bend - 1000mm1 x Female Ducting Connector - 900mm1 x CCpro 40 (1CC9402) Long Casing Extension1 x Purlin Box 1000 for RAW Cowls1 x Elta SLC500/2B-3AC - IP551 x JPA-560 Accessory Adapter Plate1 x Duct Fast Clamps - 125mm1 x Ducting 45 Degree Bend - 125mm1 x Ducting 30 Degree Bend - 400mm1 x Spiral Rapid Lock Clamp - 125mm1 x Helios SB EC 125 A SilentBox Centrifugal Fan1 x ELM 25 EX Flexible Cuff for ERM 2501 x BD7/7 centrifugal M4 0.13Kw - Galvanised Impeller - MBI Assembled1 x Ducting Y Piece - 125mm1 x Raptor SDA450/4-1EC1 x Elta SLC500-1EC -IE5 Motor- IP551 x Spigot plate - 125mm1 x CBS-80 Outlet Flange for CBT-801 x Belt Drive Cased Axial Fan - 450mm - H version1 x Acopel F400-900/1801 x AEL - Outlet Flexible Connection for TLZ450 R1 x Purlin Box 350 for RAW Cowls1 x FK 125 Fast Clamp1 x Elta SLC450/2A-3AC - IP551 x Compact SCD450/4-3AC1 x Acopel F400-560/1601 x CAB-125B - High Pressure Acoustic Fan1 x Spiral end cap - 125mm1 x Spiral Duct Grille Termination - 80mm1 x RSK400 - Back Draught Shutter1 x DA 15/15 Feet1 x FSAF450FTX 450 mounting feet (Pair)1 x AC03TO-ADS-VFS-EN-9A (Three Phase)1 x Manual Overide Switch - MOS1 x SPI-200 C Iris damper1 x GB-WK Wall Bracket For Giga Box Fans - 400-630mm1 x HRFD 400/4 EX Atex Rated 400mm Cased Axial Fan 400v1 x TUNE-R-100-3-M4 - Control Damper1 x TUNE-R-160-2-M1 - Control Damper1 x TUNE-R-100-2-M1 - Control Damper1 x GB-WK 250 Wall Bracket For Giga Box Fans - 250mm - 355mm1 x ERM180EXE Bracket1 x HRFD 315/4 EX Atex Rated 315mm Cased Axial Fan 400v1 x KV DUO 500 EC (3Ph-400v) with changeover1 x KV DUO 400 EC