• Model:5153136600

CAD-COMPACT 500 ADVANCED N8 - MVHR unit

£ 4,698.75 (excl. VAT)

£ 5,638.50 (inc. VAT)

PART NUMBER: 5153136600 Heat recovery units with high-efficiency counterflow aluminium plate heat exchanger (up to 88%) certified by Eurovent mounted in a galvanised steel double-walled enclosure with internal thermo-acoustic fireproof insulation (A1/M0) made of mineral wool 25mm mm. thickness.
Round inlet and outlet couplings. Only available in horizontal version.
Minimum outdoor air temperature -10ºC. For lower temperatures it is necessary to use preheating batteries located in the suction of the outside air.
Plug fans with backward impeller blades. Single-phase EC motors with integrated electronic protection. IP44, Class B
Low pressure drop F7 filters (ePM1 70%) in supply air side and M5 filters (ePM10 50%) in extract air side. It is possible to mount a second filter inside the unit (Delivered as accessory).
Control
Integrated control, located inside the electrical box and wired to all the components (fans, bypass, filter clogging detectors, temperature probes, etc.). Includes remote touch panel (wired). Main functionalities: Manual and automatic fan control (VAV, COP and CAV modes), by-pass management (free-cooling and defrost), control of external coils, weekly timer, alarm supervision. Modbus communication.
Applications
Air renewal in commercial premises, offices, hotels, public buildings, schools.
PDF Files


Data Sheet

2 x Single phase speed controller by auto-transformer - RMB 8.0 Amp4 x MWS 1.5 – Transformer Controller With Motor Protection2 x WS - Reversing Switch from Helios Fans1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x BEAS-control module1 x EM30-24 Control Panel Commissioning Service3 x EC6H - Reversible Group Fan Electronic Controller3 x Electronic extractor fan speed controller - FSC 1.52 x Helios HQW-200/2 - IP552 x Envirovent G4 Filter - SL-G4/F71 x CS2 Current Switch2 x Vent Axia T-Series Controller3 x Transformer Speed Control - RTRE- 12.0Amp5 x Transformer (silent) speed controller - RE 3.0 Amp2 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted2 x Helios HQW-630/4 - IP553 x TG-K3/NTC10-01 - Duct temperature sensor2 x Remote Timer Control - 13511 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven4 x Helios HQW-200/4 - IP551 x Transformer (silent) speed controller - RE 1.5 Amp2 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Two Speed Switch - REGUL-22 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS2 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Airvent ceiling fan controller1 x CBS-60 Outlet Flange for CSB/CBT-602 x TG-R room temperature sensor2 x Helios PU10 Speed Potentiometer (Flush Mounted)3 x Helios HQW-315/4 - IP551 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE2 x Transformer Speed Control - RTRE- 7.0Amp1 x MTP 10, 10K, Speed control2 x Vent Axia Silent 100T (TIMER)2 x Elta Variable Speed Drive IP66 - 0.75KW2 x Transformer (silent) speed controller - RE 5.0 Amp1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x SG-200 Fan Guard for the HQW 2001 x Isolator Switch - EFF-ISO1 x Speed Controller - REB51 x Vent Axia ACM 200 inline mixed flow duct fan1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x Transformer Speed Control - RTRE- 1.5Amp