• Model:CADB/T-HE54

CADB/T-HE 54 ECOWATT Series

£ 11,773.09 (excl. VAT)

£ 14,127.71 (inc. VAT)

Compact heat recovery unit with high- efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised steel in white. Panels are double skinned with thermo-acoustic flameproof insulation (M0), made from 25mm thick fiberglass, 25mm thickness in false ceiling versions (Models 04 to 21 ) and 50mm in Outdoor versions (Models 40 and 54). Configurable and airtight supply and exhaust spigots, suitable for horizontal and vertical installation.
Minimum outdoor temperature -10ºC. For lower temperatures it is necessary to use preheating batteries located in the suction of the outside air.

Applications
Commercial premises, offices, restaurants, public buildings, schools.
CADB-HE D ECOWATT
Heat recovery units without additional incorporated heater.
CADB-HE DC ECOWATT
Heat recovery units with built-in electric heater battery. The 3-Way valve is provided as an accessory (see accessories table for this series)
CADB/T-HE DI ECOWATT
Heat recovery units with built-in low pressure hot water coil.
Motors
Models 04 to 21: EC motors with integrated electronic protection, IP44, Class B. Models 40 and 54: Three phase motors, IP55, Class F. Fans
Plug-fan with backward curved impeller.

Filters
- F7: Low pressure F7 filters for supply air.
- M5: M5 filters for extract air.
- Possibility of mounting a second filter (accessory).
It is possible to complement the heat recovery unit with a specific range of water and direct expansion coils. Also available, the exclusive module IAQ with high efficiency VOCs and particles filtration that guarantees the filtration and purification of the outdoor air.

Additional information
CADB-HE- Single fase (1/230V 50 Hz).
CADT-HE- Only DI versions: single fase fans and three fase coils (3/400V 50Hz).
Airflows from 450 to 5.400 m 3 /h at 150 Pa of static pressure available.
All versions and models include by-pass.
Mounting flexibility provided by the interchangeable side panels.
CADB/T 40 and 54 models with frequency converter included inside the unit (an inverter for each fan, which allows independent adjustment of supply and extract airflow).
1 x 1mtr Round Ducting - 100mm1 x FSD-TD 600 x 600 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x Elta 10 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 2amps3 x EC6H - Reversible Group Fan Electronic Controller2 x Airvent ceiling fan controller1 x Elta 3 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 8amps4 x Elta 6 Amp Electronic single phase speed controller with TK1 x ELTA - Single Phase Transformer 16amps1 x EFSC-3N- Single Phase Speed Control3 x Elta 3 Amp Electronic single phase speed controller with TK2 x Elta 2 Amp Electronic single phase speed controller.1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x COM-31 x AIRVENT speed control - AIR4019611 x ELTA - Single Phase Transformer 4amps1 x ELTA - Single Phase Transformer 12amps1 x Elta 6 Amp Electronic single phase speed controller.1 x EFSC-6N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 10amps1 x D2E-146-AP47-751 x Small Centrifugal Fans CBM/2-133/190 185w2 x REU 7amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost2 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans3 x Helios TSW 3 Amp Transformer speed controller1 x RDS 11 Helios Transformer Controller With Motor Protection2 x Helios TSW MCB Amp Transformer speed controller2 x Transformer 5 Speed Controller - ATC1-4TK1 x RTRD - Three Phase Speed Controller - 2 Amp2 x Helios TSW 1.5 Amp Transformer speed controller3 x Vent Axia ACM 125 inline mixed flow duct fan2 x Helios TSW 0.3Amp Compact Transformer speed controller1 x Vent Axia ACM 150 inline mixed flow duct fan2 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Remote controller FLEX - for VEKO INT1 x Transformer 5 Speed Controller - ATC1-10TK1 x Transformer 5 Speed Controller - ATC1-8TK1 x DEF-140T Inlet Guard for the CBT-100N2 x CS2 Current Switch3 x MWS 3 – Transformer Controller With Motor Protection1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Systemair Save Connect 2.0 Internet Module1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x TD EVO-100 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Vent Axia SC5001 - Speed controller3 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x ERR 20/1 Centrifugal inline fan1 x MV-B Dual Switch for use with Helios HQW plate fans,1 x Isolator Switch - ISOSW1 x 7 Day Programmable TIMECLOCK1 x WS - Reversing Switch from Helios Fans2 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Multi Input Run On Timer - 0 - 20min - CFCU2 x Temperature Fan Speed Controller - ATCP4-WMS1 x Helios TSW 7.5 Amp Transformer speed controller1 x Push Timer Switch - ZA42 x Single phase speed controller by auto-transformer - RMB 1.5 Amp2 x MWS 1.5 – Transformer Controller With Motor Protection2 x Helios HQW-200/2 - IP551 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x ERR 31/1 Centrifugal inline fan1 x Two Speed Switch - REGUL-21 x Electronic extractor fan speed controller - FSC 1.51 x Vent Axia T-Series Controller1 x Transformer Speed Control - RTRE- 12.0Amp1 x Helios HQW-630/4 - IP55