• Model:CFDM-125

CFDM-125 Circular Twin Blade Fire Damper

£ 48.14 (excl. VAT)

£ 57.77 (inc. VAT)

CFDM-125 Circular Twin Blade Fire Damper

Fire dampers are shutters in duct systems of air-conditioning devices that prevent spreading the fire and combustion products from one fire segment to the other one by means of closing the air duct in the points of fire separating constructions. Dampers blade automatically closes air duct using a shutting spring. The damper is sealed with a plastic foam packing against smoke penetration after closing the blade. At the same time, the damper blade is bedded in a material which enlarges its capacity and air´proofs the air duct. Fire damper can be directly equipped with a dish valve in both combinations - exhaust and supply.
Damper characteristics

• CE certified acc. to EN 15650
• Tested in accordance with EN 1366-2
• Classified acc. to EN 13501-3+A1
• Fire resistance EIS 120, EIS 90, EIS 60
• Internal leakage class 2 acc. to EN 1751, external leakage is equal to ducting system
• Corrosion resistant acc. to EN 15650
• ES Certificate No. 1391-CPR-2018/0129
• Declaration of Perfomance No. PM/CFDM/01/16/1
Working conditions:
Exact damper function is provided under the following conditions:
a) Maximum air circulation speed: 12 m.s-1
Maximum pressure difference: 1500 Pa
b) The air circulation in the whole damper section must be secured as steady on whole surface.
Operation of the damper does not depend on the direction of air circulation. The dampers can be located in an arbitrary position,
Dampers are suitable for ventilation systems, where air does not content any abrasive, chemical or adhesive particles.
Dampers are designed for macroclimatic areas with mild climate according to EN 60 721-3-3.

Temperature in the place of installation is permitted to range from -30°C to +50°C.
1 x Plastic Kitchen Extractors - CK-60F1 x ERM 18 protection guard - SGM 18 EX1 x FSD-TD 500 x 400 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x 220x90mm Insulated Rectangular Horizontal 90° Bend1 x Spiral end cap - 125mm1 x 220 x 90mm Duct to Fitting Connector for use with Insulated Thermal Ducting1 x PM24-TF, AC 24V Damper Actuator, Spring Return, 2 x SPDT, 72C Thermal Fuse1 x Spiral end cap - 100mm1 x 220x90mm Flat Channel Connector1 x 204x60mm 90 Degree Vertical Bend1 x Hideaway SH150-1ECL1 x AEL - Outlet Flexible Connection for TLZ450 R1 x KVK Slim 125 - Low profile Semi Acoustic Box Fan1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 4501 x FSD-TD 450 x 450 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM24-TF (SC)1 x FSD-TD 225mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x AL 315 D2 01 - High Performance Long Cased Axial Fan (3 phase)1 x Acopel F400-225/1601 x VKS 355-500 Automatic shutter1 x 220x90mm Equal T Piece1 x Helios - RDW 400/4 - Centrifugal Roof Fan1 x CTHB/6-2001 x Helios SB-250-C SilentBox Acoustic Inline Fan1 x Vent Axia SABRE Plate Mounted Sickle Fans - VSP500141 x EZQ 20/2 B - High Performance Plate Axial Fan1 x FSD-TD 400 x 200 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x LAL 1000 D4 Mounting Flange1 x FSD-TD 400 x 250 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x Duct Mounted Filter Box With G2 Paper AND Metal Washable Filter - 100mm1 x 204x60mm to 125mm Insulated Straight Adapter1 x 220 x 90mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x 125mm Thermal Duct to Fitting Connector - SST-125-DFCON1 x 204x60mm Insulated Rectangular Horizontal 90° Bend1 x 204x60mm x 1m Insulated Rectangular Duct