Fire rated extractor fans and Smoke Extractor Fan Motors. Most normal fans only operate up to about 70 degrees Celsius, but these used when extra heat tolerance is required. Most have both a continuous and a maximum (for so many hours) rating.
Axial fans, VA series For Special Applications needing high temperatures.
Max Temp: 60 degrees C. Suitable for server/switch cabinets, PC's etc.
Please note, only the VA14/2 is currently available....
Axial fans, VA series For Special Applications
VA 12/2 T - High Temp Model 150*c
119mm Body, 150m3/hr, 18W
Designed for:
Operating conditions:
- cooling of electronic control panels
- vent...
The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm miner...
Smoke extract axial fan Series AXC(B), tested according to EN 12101-3 for 300°C-120min - AXC 450-10/23°-2 (B) (3,00 kW) S
The Systemair AXC(B) range of long cased medium pressure axial fans is a...
Smoke extract axial fan Series AXC(B), tested according to EN 12101-3 for 300°C-120min - AXC 315-10/16°-4 (B) (0.75Kw)
The Systemair AXC(B) range of long cased medium pressure axial fans is avai...
Smoke extract axial fan Series AXC(B), tested according to EN 12101-3 for 300°C-120min - AXC 1000-10/22°-4 (B) (15.0Kw)
The Systemair AXC(B) range of long cased medium pressure axial fans is ava...
Centrifugal Hot air/Gas Blower.
Provides fast and efficient hot air distribution from your heating source to any of your rooms.
The motor must be placed out off-airflow!
< 180 to 240 Degrees Celsi...
200 °C constant operation and 400 °C / 2h
Motor outside of air stream
Speed controllable
Swing-out fan unit
With condensate and grease drain
Certified according to EN 12101-...
200 °C constant operation and 400 °C / 2h
Motor outside of air stream
Speed controllable
Swing-out fan unit
With condensate and grease drain
Certified according to EN 12101-...
The KBR/F fans smoke extract unit are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard temperature up to 200°C.
The KBR/F units h...
In accordance with Commission Regulation (EC) no 640/2009 of the European Parliament - eco-design requirements for electric motors - the new international efficiency classes are binding as of 16 June ...
In accordance with Commission Regulation (EC) no 640/2009 of the European Parliament - eco-design requirements for electric motors - the new international efficiency classes are binding as of 16 June ...
ILHT/4-560 MV (230/400V50HZ) N8
Range of direct-driven rectangular in-line fans designed for smoke extraction in fire conditions and certified F400-120 (CE marked). All models are suitable for air s...
ILHT/4-500 MV (230/400V50HZ) N8
Range of direct-driven rectangular in-line fans designed for smoke extraction in fire conditions and certified F400-120 (CE marked). All models are suitable for air st...
Application:
Smoke and hot gas extraction in case of fire. Extraction of stale air from commercial and
industrial premises. Extraction of pollutants in professional kitchens.
Installation in all po...
Application:
Extraction of pollutants in professional kitchens.
Installation in all positions and connection on all faces. Air stream temperature up to 120°C in continuous with motor at 40ºC max. ...
Application:
Extraction of pollutants in professional kitchens.
Installation in all positions and connection on all faces. Air stream temperature up to 120°C in continuous with motor at 40ºC max. ...
ILHT/6-035 *230/400V 50*
Range of direct-driven rectangular in-line fans designed for smoke extraction in fire conditions and certified F400-120 (CE marked). All models are suitable for air stream te...
Cabinet fans especially designed for use and distribution of heat produced by fireplaces, suitable for continuous extraction of airstreams at temperatures up to 180 º C.
All casings are manufactured...
Designed for moving dirty, humid and hot air volumes up to max. 120°C.- Motor located outside of airflow.
Temperature insulated partition panel between motor and impeller, lined with 20mm thick fl...