• Model:FSD-TD350200

FSD-TD 350 x 200 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)

£ 404.25 (excl. VAT)

£ 485.10 (inc. VAT)

FSD-TD Features and Benefits

• Tested and certified installation variants of the FSD-TD are available to cover masonry walls, dry walls, batt walls and floors. These cover the majority of applications/supporting constructions that are required to maintain compartmentation and protect escape routes and areas with sleeping risk.
• All BSB tested installation methods give at least a ES120 (E120S) classification, usually only limited by the wall construction used. This is extended to 4 hours when installed using a HEVAC frame in a masonry/blockwork floor or wall.
• Sleeve and angle methods, HEVAC frame methods, angle frame methods, cleat and drop rod methods and batt infill methods are available. • Some rarer installation applications are covered by assessment/test information to BS 476-20/22.
• Minimum size 100 x 100 (not adapted from a larger size by reducers) available for space saving.
• Circular connection - base damper does not increase, thus saving space and transport volume.
• Single section size up to 1000 x 1000 in millimetre increments.
• Multi-section configurations are available to specific customer requirements, but will be subject to Building Control Authority approval.
• No duct sleeve, again giving space savings over other models and savings on transport volume.
• Standard construction is a fully welded galvanised steel case, which gives a casing leakage that complies with Class C ductwork leakage specifications.
• Blades have folded safe-edges to aid site safety.
• Galvanised mild steel DX 51D Z275, Ferritic (430) type 1.4016 or Austenitic (316) 1.4401 grade stainless steels for the blades and case are available for specific customer requirements.
• All blade and motor connecting drives are removed from the airstream and are fully enclosed. This gives both increased free area through the damper and protection to the mechanisms.
• Electrical Actuators (24VAC/DC, 230VAC,) have a less than 60 second motoring time. They have multi-position fitting and, being remote from the duct, allow space savings.
• All damper/actuator assemblies are mechanically tested prior to despatch (NOTE: The thermal fuse needs to be fitted/installed through the duct wall by the customer when the damper is installed).
• Actuators may be supplied separately to the dampers for site fitting by others to suit customer specific requirements.
• The FSD-TD range is fully compatible with the BSB range of smoke control panels, fire alarm systems, building management systems (BMS) and other bespoke control systems.
• The BSB FSD-TD has a strong and robust design to both meet the exacting fire testing requirements and be resilient to site handling. This is supported by sound production techniques which result in a quality product.
• All the above, supported with BSBs enviable delivery performance, provide an unbeatable combination.
1 x Soler & Palau TCBT/6-710/L - IP651 x DDMP 09/07 Mounting Flange1 x CVAT Acoustic Kitchen Fan & Inverter Kit - CVAT/4-6000/500 ND - Pack 61 x Ducting 45 Degree Bend - 710mm1 x DDMP 12-12 FLANGE1 x Soler & Palau - HCBB/2-315/H - IP651 x SEL355/4-1AC1 x Flat Roof Terminal -OFT 5 - Bitumen1 x 204 x 60mm Duct to Fitting Connector for use with Insulated Thermal Ducting1 x DPD SAT Delivery Surcharge1 x ELTA - Single Phase Transformer 16amps1 x VKS 355-500 Automatic shutter1 x AL 315 D2 01 - High Performance Long Cased Axial Fan (3 phase)1 x MD - Motor Protection Switch (3 Phase)1 x Soler & Palau - HCFT/4-1000/H-X - IP551 x Differential Pressure Switch - 50 - 500 Pa - IP541 x ACO3/B Changeover Panel (Three Phase)1 x Access Door for Circular Duct - 400 x 300 - SIZE 631 x KVK SLIM 200 EC - Centrifugal Circular Duct Fan1 x 18M - 80mm PVC flexible ducting1 x ASF 355-500 inlet flange DVS1 x Soler & Palau - Contra Rotating TCBTx2-450 - IP651 x Ducting 90 Degree Bend - 560mm1 x HCGT/2-315/L-AMXN E7201 x DDMP 09/09 Mounting Flange1 x HCFT/4-400mm plastic impeller plate fan1 x 125mm Insulated 90 Degree Bend1 x TTT/4-630/H N 1,5KW (230/400V50HZ)EXEIIT3 VE Atex Unit1 x Ducting 90 Degree Bend - 900mm1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Singleflow SSDL500-1EC1 x 7 Day Programmable TIMECLOCK1 x 100mm Round 45 Degree Bend1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT350/4-3AC1 x HCFT/4-315mm (B-FLOW) plastic impeller plate fan2 x Time Delay Unit - DT20B1 x Elta Wall Cowl SWC25/311 x Ancillary Pack for SLC-900 for SLC900/4A-3AC and SLC900/8-3AC1 x Elta SPA400/4-1AC - IP541 x Elta SLC1000/6A-3AC - IP551 x Silentub - STUB 1001 x 100mm Round Connector with Damper1 x CBMT/Q 500-17 3 HEATER KIT1 x Flanged Spigot - 125mm1 x Elta 6 Amp Electronic single phase speed controller.1 x BEAS-control module1 x FAST-TRACK RANGE 75mm - Valve Adaptor 90° 125mm1 x Elta SLC450/4-3AC - IP551 x Duct Fast Clamps - 125mm1 x HQS Bathroom Axial Flow Fan - 125mm1 x Etaline 355mm E4 011 x Female Ducting Connector - 710mm1 x LCA403226 - Long Cased Axial Fan1 x Raptor SDA400/4-1AC1 x Elta SLC630/4-1AC - IP551 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT400/4-3AC1 x MEV 160 & 300 Additional Spigots1 x Etaline Max-Fan - 315mm - E2 01