• Model:HR200WK

HR200WK single room heat recovery unit

£ 719.18 (excl. VAT)

£ 863.02 (inc. VAT)

A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Transformer Speed Control - RTRE- 5.0Amp1 x DDMP 12-12 3F 1810W M6A4 DG01 x Flakt Woods ME 1.3 speed controller 3amp - EA9011581 x 100mm Round Connector with Damper1 x Elta SCP400/4-1AC - IP552 x DDMP 12-12 3F 5700W M6M0 DG71 x Duct Termination with Mesh - 450mm2 x DDMP 10-10 1F 1000W M6A2 DA51 x HIMF - Mixed Flow Fan 125mm Inline Fan3 x DPD 12PM Delivery Surcharge3 x CBS-100 Outlet Flange for CBT-1001 x Binks Bullows - Spray Booth Filter1 x Duct Termination with Mesh - 150mm1 x CCpro 40 (1CC9402) Long Casing Extension3 x ACOAS/ AC/EC Auto Changeover 8Amp5 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan2 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt C VR1 x DS-2/2 2-Speed Switch IP54 (Single Phase)4 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)2 x KAD-225-F400 Rectangle Flexible Connector1 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven2 x Duct Termination with Mesh - 250mm1 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)2 x RUCK MTP 20, 10K, Speed control3 x CBB-80N Centrifugal2 x TUNE-R-200-3-M3 - Control Damper1 x FU 15 16 Frequency Inverter3 x DDMP 12-09 1F 1800W M6A4 DA81 x Spiral end cap - 355mm4 x Biflow SB315-CON4-3 - High Temperature Bifurcated Fan1 x Potentiometer EGH 01 - for DDMP Fans3 x ELTA - Three Phase Transformer 3amps2 x CAD-COMPACT 900 ADVANCED N8 - MVHR unit2 x Twinflow STDL315-1EC2 x Duct Termination with Mesh - 400mm2 x Run On Timer - 5s - 4hrs - RT5A2 x TecFire Intumescent Damper - Rectangular 400x400mm2 x CBM Low Pressure Centrifugal Fan - CBM 7/7 6 Pole 72watt CVR2 x Backdraught Shutters 039-SFSV-63/711 x VTR 500 STD Filter Kit1 x Round ceiling diffuser 300mm2 x KBA- Inlet Mounting 2502 x SDD-U Anti Vibration Pads1 x Quietflow SQS250-1ECL - Centrifugal Box Fan1 x CBM 7/7 147w 4P RE-VR2 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF315/4-1AC - Single Phase1 x DDMP 12-12 1F 1800W M6A4 DA82 x Universal Pipe Fixing Clip1 x CBM Low Pressure Centrifugal Fan - CBM 10/8 4 Pole 373watt CVR1 x Elta HXP 800mm 6-Pole (Three Phase)1 x DDMP 09-07 1F 1000W M6A0 DA51 x DDMP 10-08 1F 1000W M6A2 DA5