The Kitchavent System is designed to control nuisance grease, smoke and odour discharge from commercial kitchens in line with DW 172 and the DEFRA standards for nuisance control from kitchen extract systems.

The Kitchavent system can be installed in any convenient position within the kitchen extract duct run from the Canopy to the extract fan.

Most often used for a variety of cafe's, restaurants etc where odour control is required.

The modular system allows for airflows ranging from 0.2m3/s in the smallest module up to 2.12m3/s in the largest unit, and then multiple units can be utilised to cater for any larger airflows or greater contact times. The Kitchavent System can be used to design systems that will meet any contact time required for odour control. Typically this is defined by local authority guidance, or advised by a systems designer. (Typically 0.1 seconds to 0.8 seconds depending on cuisine and discharge point.)

Consists of Dust pre-filters and banks of activated carbon panel filters in a complete housing.

Please contact us for a quote including cooking type, contact time, airflow etc. for accurate price as this price is just a guide - Please complete the Risk Assessment for Odour – For Restaurants and Commercial Kitchens form on the Download Tab

Download specifications
href="https://www.justfans.co.uk/catalogues/kitchavent1.pdf">HERE.
2 x ENV 100 12v transformer SELV4 x ACO8AC/EC AutoChangeover panel1 x Biflow SB400-CON2-3 - High Temperature Bifurcated Fan2 x CO2 Room Sensor - CO2-R1 x KBA- Inlet Mounting 2801 x VTR 300 STD Filter Kit1 x TUNE-R-100-2-M1 - Control Damper1 x SPI-100 C Iris damper1 x Elta Standard Ambient Flexible Connector - 560mm3 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR2 x Contactor Interface Station - CI91 x TUNE-R-200-3-M0 - Control Damper (NO ACTUATOR)2 x Silentub - STUB 1001 x TD160-NT Mixvent - 100mm - TD160 Timer1 x Duct Termination with Mesh - 250mm2 x DDMP 12-12 3F 5700W M6M0 DG71 x Helios RR-250-C Centrifugal inline fan2 x Duct Termination with Mesh - 450mm2 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x SAVE VSR 300 heat recovery unit2 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan1 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 736watt CVR1 x CBA-100 Inlet Flange for CBT-1002 x KAD-225-F400 Rectangle Flexible Connector1 x Biflow SB315-CON4-3 - High Temperature Bifurcated Fan1 x Duct Termination with Mesh - 500mm3 x HIMF - Mixed Flow Fan 100mm Inline Fan2 x TUNE-R-200-3-M5 - Control Damper2 x CAD-COMPACT 900 ADVANCED N8 - MVHR unit2 x Flat Roof Terminal -OFT 5 - Asphalt2 x CBT-130N Centrifugal ATEX II 3D ExtD 125*C4 x DDMP 10-10 1F 1000W M6A2 DA52 x TUNE-R-180-2-M5 - Control Damper1 x VEKA INT 2000/15.0-L1 EKO1 x ADH E0-450 Flange - 0450 ADHE/RDHE3 x Duct Termination with Mesh - 150mm1 x Elta SCP400/4-1AC - IP553 x CBS-100 Outlet Flange for CBT-1002 x ELTA - Three Phase Transformer 3amps3 x DDMP 12-09 1F 1800W M6A4 DA83 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)2 x RUCK MTP 20, 10K, Speed control1 x DA9/9-NT1 x TecFire Intumescent Damper - Rectangular 400x400mm2 x Speed Controller - REB161 x KBA- Inlet Mounting 2251 x Skyflow SSR Horizontal Roof Cowl SSR80B1 x Soaker Sheet to suit RA8001 x Purlin Box 800 for RAW Cowls2 x Flanged Damper 019-0560-STD1 x KBA- inlet mounting flange for CRMT 2502 x TUNE-R-250-1-M1 - Control Damper1 x RDH Flange - 03151 x RDH Flange - 02501 x Ancillary Pack for SLC-800 for 4 Pole and SLC-800/6B-3AC2 x TUNE-R-160-3-M0 - Control Damper (NO ACTUATOR)2 x PM230-TF, AC 230V Damper Actuator, Spring Return, 2 x SPDT, 72C Thermal Fuse1 x FU 22 25 Frequency Inverter1 x CBM 9-9 550w 4P VR (Open Motor)1 x EX 140A-2 (Three Phase) Centrifugal Fan (ATEX)1 x Access Door for Circular Duct - 250 x 150 - SIZE 152 x TUNE-R-160-1-M1 - Control Damper1 x Transformer Speed Control - RTRE- 5.0Amp1 x SPI-200 C Iris damper2 x Nicotra RDH G2E7-04502 x Spiral end cap - 355mm2 x TUNE-R-160-2-M3 - Control Damper1 x Biflow SB250-CON2-3 - High Temperature Bifurcated Fan1 x HIMF - Mixed Flow Fan 125mm Inline Fan1 x SDD-U Anti Vibration Pads2 x TUNE-R-250-2-M2 - Control Damper1 x TD Mixvent 1100/250 EEXEIIT32 x DDMP 12-12 1F 1800W M6A4 DA81 x Duct Termination with Mesh - 400mm1 x DDMP 10-08 1F 1000W M6A2 DA51 x TUNE-R-200-3-M3 - Control Damper1 x 110 x 54mm Round to Rectangular Adaptor - Long1 x RDH Flange - 04001 x Helios PA10 Speed Potentiometer1 x Two Speed Switch - REGUL-22 x TUNE-R-315-3-M1 - Control Damper1 x Kitchavent 2000 Odour control System - 18152521 x Potentiometer EGH 01 - for DDMP Fans1 x Flanged Damper 019-0500-STD1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x Run On Timer - 5s - 4hrs - RT5A1 x Elta 3 Amp Electronic single phase speed controller.1 x 220x90mm x 1m Insulated Rectangular Duct1 x Chaysol DA 9/9 3 speed1 x Elta SCP350/4-1AC - IP551 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF315/4-1AC - Single Phase1 x TUNE-R-160-3-M2 - Control Damper1 x DPD 12PM Delivery Surcharge1 x MWS-75 Transformer controller with TK -7.5A1 x Jetflow Silent SJMF-S 200-1EC1 x GRA-100 External Grill by S&P1 x 204x60mm Insulated Rectangular Horizontal 90° Bend1 x DDMP 10-08 FLANGE1 x RDH Flange - 04501 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Universal Pipe Fixing Clip1 x Elta SLC560/4C-3AC - IP551 x Helios VARW 450/4 - TK1 x Vent Axia ACM 200 inline mixed flow duct fan
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...