• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x CK-60F Kit1 x Flexible PVC Ducting - 15 Mtr3 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Helios ZNE Electronic Fan Overrun Timer3 x Push Timer Switch - ZA43 x Multi Input Run On Timer - 0 - 20min - CFCU2 x 7 Day Programmable TIMECLOCK1 x Same Day Shipping Surcharge - City Sprint1 x Northern Ireland Pallet Surcharge1 x DPD 12PM Delivery Surcharge1 x DPD 10:30AM Delivery Surcharge1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Transformer 5 Speed Controller - ATC1-4TK2 x Helios TSW 0.3Amp Compact Transformer speed controller2 x Vent Axia ACM 150 inline mixed flow duct fan1 x Helios TSW MCB Amp Transformer speed controller2 x Systemair Save Connect 2.0 Internet Module2 x Helios TSW 1.5 Amp Transformer speed controller1 x MWS-75 Transformer controller with TK -7.5A2 x MV-B Dual Switch for use with Helios HQW plate fans,2 x MWS 3 – Transformer Controller With Motor Protection1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Elta 6 Amp Electronic single phase speed controller with TK1 x ERR 20/1 Centrifugal inline fan1 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Transformer 5 Speed Controller - ATC1-8TK1 x Helios TSW 3 Amp Transformer speed controller1 x TDP-D Pressure Sensor with Display1 x RTRD - Three Phase Speed Controller - 2 Amp1 x MWS 5 – Transformer Controller With Motor Protection Unit2 x Vent Axia ACM 125 inline mixed flow duct fan1 x Transformer speed controller - ATC1 - 1.5 Amps1 x CS2 Current Switch1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x RTRD - Three Phase Speed Controller - 4 Amp1 x TD EVO-100 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Remote controller FLEX - for VEKO INT1 x Transformer 5 Speed Controller - ATC1-2TK1 x Helios TSW 7.5 Amp Transformer speed controller1 x DEF-140T Inlet Guard for the CBT-100N1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Transformer 5 Speed Controller - ATC1-10TK1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Insulated extract Plenum 8+11 x Insulated extract Plenum 6+11 x Elta 3 Amp Electronic single phase speed controller with TK2 x MWS 1.5 – Transformer Controller With Motor Protection1 x Two Speed Switch - REGUL-21 x WS - Reversing Switch from Helios Fans1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Elta 10 Amp Electronic single phase speed controller.1 x Helios HQW-630/4 - IP552 x ERR 31/1 Centrifugal inline fan1 x REE-1 Electronic Speed Controller2 x Transformer (silent) speed controller - RE 3.0 Amp1 x Electronic extractor fan speed controller - FSC 1.51 x CBS-60 Outlet Flange for CSB/CBT-602 x Helios HQW-200/4 - IP551 x Speed Controller - REB31 x Transformer (silent) speed controller - RE 1.5 Amp1 x Speed Controller - REB51 x Multileaf Volume Control Dampers -500/500 Rectangular Flanged2 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x ELM 18 EX Flexible Cuff for ERM 181 x Speed Controller - REB101 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x Speed Controller - REB61 x Elta Variable Speed Drive IP66 - 0.75KW1 x Transformer Speed Control - RTRE- 7.0Amp1 x REB-CVF 0-10v Controller1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT2 x TG-K3/NTC10-01 - Duct temperature sensor1 x Helios HQW-200/2 - IP551 x Skyflow SSR Horizontal Roof Cowl SSR80B1 x Helios HQW-315/4 - IP551 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x Transformer Speed Control - RTRE- 5.0Amp1 x SG-200 Fan Guard for the HQW 2001 x Elta Variable Speed Drive IP66 - 2.2KW1 x Speed Controller - REB1-N1 x MTP 10, 10K, Speed control1 x TUNE-R-200-3-M1 - Control Damper1 x Multiflow SMB550/4-1AC1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Envirovent G4 Filter - SL-G4/F71 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x Transformer Speed Control - RTRE- 1.5Amp1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x PIR Sensor - PIR21 x Silent 100 Window Kit - windowS1 x KKS 100 silencer-section - For use with the MUB 100 size Fans.1 x TD Mixvent 800/200 EEXEIIT31 x Helios HQW-250/4 - IP551 x QPTW 250C Acoustic Twin Fan with Controller1 x DDMP 12-12 3F 1810W M6A4 DG01 x Speed Controller - REB1
BD9/9 centrifugal M4 0.35Kw
BD9/9 centrifugal M4 0.35Kw
£ 399.00 now £ 350.00
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...