• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Elta SPA350/4-1AC - IP441 x Multileaf Volume Control Dampers -600/600 Rectangular Flanged1 x HRST/6-710-24 BZ C Rotorex Sickle bladed fan1 x Helios AV200 External Wall Fan1 x Soler & Palau - HCBT/4-710/H - IP651 x Elta Unpodded Silencer Melinex 1D-500mm1 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF350/4-1AC - Single Phase1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x Soler & Palau - HCBB/2-355/H - IP651 x Elta Unpodded Silencer Melinex 1D-450mm1 x Elta Unpodded Silencer 1D-800mm1 x AW Sileo EC Plate Axial Fan - Three Phase - 710mm1 x CRHB/6- 315mm Roof mounted Fan - Horizontal discharge1 x Soler & Palau - HXBR/4-355/H - IP541 x Female Ducting Connector - 100mm1 x Elta Unpodded Silencer Melinex 2D-450mm1 x Soler & Palau HXM-350mm1 x Elta SPA400/46-3AC - IP541 x Ductwrap Insulation DW501 x Elta Unpodded Silencer 1D-560mm1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x BOX Hood - BOX-INOX-6001 x HRT/4-355-BPN1 x Soler & Palau - HXTR/4-355/H - IP541 x Hydor HPA400/6-1A1 x External weather louvre 2728mmW x 1630mmH1 x SPI-200 C Iris damper1 x Onda Cristal 900 Kitchen Extractor Hood1 x HA-600 SLIM Cooker Hood - Stainless Steel1 x AL 315 EC 01 AXIALINE - High Performance Long Cased Axial Fan1 x Frequency converter RUCK - FU 075 211 x FU 15 40 Frequency Inverter1 x EDM 100 CHZ1 x CONTROL ECOWATT - Basic1 x Elta Wall Cowl SWC25/311 x RVK-EX 315D4 (ATEX) - 315mm Atex Rated Centrifugal Fan1 x 220x90mm Elbow Bend with 125mm Fixed Spigot1 x AL 355 Mounting Feet (Pair)1 x Fresh Air control carbon filter - 125mm1 x HQS Bathroom Axial Flow Fan - 125mm1 x HIMF - Mixed Flow Fan 150mm Inline Fan1 x 150mm Round Connector1 x FU 075 04 Frequency Inverter (IP20)1 x Soler & Palau - Contra Rotating TCBTx2-450 - IP651 x Etaline 630mm - D4 01 3 Phase1 x MFA-AR/AXC 315 mounting foot1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x CBT-100 N (230/400V50HZ) LG270-EXDIIBT41 x Economy Airvent 100mm Fan with Timer/Humidistat/Pullcord1 x 100mm Wall Duct - 350mm1 x Capacitor 20uf for use with the EBM D2E range1 x FU 22 25 Frequency Inverter1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x FSAF450FTX 450 mounting feet (Pair)
Reviews
Airvent Ceiling Sweep Fan - 36 inch - 444122
Airvent Ceiling Sweep Fan - 36 inch - 444122
£ 59.84

Fitted 2 Of These Excellent Fans in a Community Club to shif...