• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Ducting 45 Degree Bend - 200mm1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Elta Wall Cowl SWC35/401 x HV Wall Mounted Belt Drive Fan 1000mm 220V to 240V / 50Hz 0.75kW - Single Phase1 x Helios TSD 5.5 Transformer Speed Control (400v)1 x Duct Quick Suspension Rings with Clasp - 200mm1 x ATEX rated 3-phase Speed Control - R-DK4 KT (EX)1 x Flanged Spigot - 355mm1 x Ducting 15 Degree Bend - 250mm1 x FU 22 04 Frequency Inverter1 x External weather louvre 500w x 500h - WL501 x Soler & Palau - HCFT/4-1000/L-X - IP551 x HCFT/6-1000-HX plastic impeller plate fan1 x ELTA - Three Phase Transformer 3amps1 x Acoustic MiniBox Fan - MINI-BOX 2001 x BDRAX 250-E2 Cased Axial External Rotor Fan1 x Spiral Ducting 3 Meters - 355mm1 x Spiral Duct Grille Termination - 200mm1 x Male Ducting Connector - 200mm1 x Elta Variable Speed Drive IP66 - 7.5KW1 x KVK Slim 200 - Low profile Semi Acoustic Box Fan1 x AW Sileo EC Plate Axial Fan - Three Phase - 710mm1 x Spiral Duct Grille Termination - 250mm1 x Synthetic Air Filter Media - 15mm x 1000mm x 1000mm1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x Soler & Palau - HCBT/6-1000/H - IP551 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x 150mm - 100mm Stainless Steel Ducting Reducer1 x Circ.connection-125 fo EX-140 ATEX unit1 x Elta Wall Cowl SWC56/631 x Elta SPA710/6-3EC1 x Elta Cased Axial Flange - 400mm1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Curved boot - 200mm1 x Female Ducting Connector - 560mm1 x Elta Quietflow Twin SQT150-1ECL1 x Pressed Ducting Saddle - 450mm1 x Quietflow SQS500-1ECL - Centrifugal Box Fan1 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Soler & Palau - HCBT/4-800/L-AX - IP551 x RVK-EX 315D4 (ATEX) - 315mm Atex Rated Centrifugal Fan1 x Flexible PVC Ducting - 204x601 x Soler & Palau - HXTR/6-800/H - IP541 x Casals Circular Outlet Connection Flange - 5102018031 x HV Wall Mounted Belt Drive Fan 800mm 400V / 50Hz 0.75kW - Three Phase1 x Elta Quietflow Twin SQT500-1ECL1 x Soler & Palau - HXTR/12-800/28-A1 x AXC 315-6/11-2(B)-PV 300*C - Smoke Extract Fan1 x Elta Qube SQU Centrifugal Box Fan - SQU3/4-3 - Three Phase1 x Soler & Palau TCBB/6-710/L - IP651 x TD500 Mixvent - 160mm - TD500(5211302400)1 x Spigot plate - 560mm1 x Soler & Palau TCBT/4-710/H - IP651 x Inline Hepa filter with housing & pre-filters1 x Airbrick Grille with flange - 204 x 60mm1 x Mellizo XL EcoWatt 3000 - Twin Fan1 x Ducted Outlet Option for H14 - HAP5001 x KV DUO 250 EC1 x Curved boot - 560mm1 x Purlin Box 630/710 for RAW Cowls1 x DV-ROF-V-315 Roof mounted unit1 x Jetflow-HIT Metal inline - 125mm1 x 204x60mm 90 Degree Vertical Bend1 x Soler & Palau - HCBT/6-800/H - IP65