• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Duct Split Rings (Pair) -560mm1 x SQUARE MIXED FLOW FAN - MFQ 560mm (Three Phase)1 x KABT/4- 12000/5601 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)1 x Helios GigaBox 450mm GBD 450/4/4 centrifugal1 x Ducting 90 Degree Bend - 560mm1 x Kitchen Grease Filter - Mesh Type NON standard 390mm x 240mm x 40mm Actual1 x Female Ducting Connector - 100mm1 x Kitchen Grease Filter - Mesh Type Non standard 296mmx296mmx22mm1 x Singleflow SSDL125-1EC1 x Kitchen Grease Filter - Mesh Type Non standard 450mm x 150mm x 22mm ( CEF450 Replacement)1 x Ducting 15 Degree Bend - 560mm1 x Helios GigaBox 560mm GBW 560/4 centrifugal1 x Elta Turboflow-TF - 630mm - Three phase1 x Ducting 45 Degree Bend - 80mm1 x Inline Hepa filter with housing & pre-filters1 x Anti Vibration Mounts - Small - Pack of 4 - AVM21 x Elta SLC560/4B-3AC - IP551 x Soler & palau TCBT/2-250/H - IP441 x Female Ducting Connector - 80mm1 x Soler & Palau TCBT/4-560/L - IP651 x Quietflow SQSDCV100-1ECL - Centrifugal Box Fan1 x Ancillary Pack for SLC-800 for SLC800/6A-3AC1 x Raptor SDA630/6-1AC1 x HRT/4-630/25-BPN C1 x Spiral end cap - 150mm1 x CBT-80N Centrifugal ATEX II 2G Exe II T31 x 150mm Round Connector1 x Belt Drive Cased Axial Fan - 630mm - H version1 x Elta Turboflow-TF - 630mm - Single phase1 x 150mm - 100mm Stainless Steel Ducting Reducer1 x Flanged Spigot - 150mm1 x Belt Drive Cased Axial Fan - 560mm - H version1 x 125mm Round Condensation Trap1 x Raptor SDA630/46-3AC1 x Ducting T Piece Equal - 80mm1 x HRB/6-630-30-APN1 x Ancillary Pack for SLC-4001 x Elta SLC560/4B-1AC - IP551 x Metal Inline Fan - VENT-355N1 x HRST/4-710-20 BPN C Rotorex Sickle bladed fan1 x Purlin Box 300/315 for RAW Cowls1 x Soler & Palau TCBT/4-800/K - IP651 x Duct Termination with Mesh - 315mm1 x Soler & Palau TCBB/4-630/L - IP651 x Universal Pipe Fixing Clip1 x Purlin Box 350 for RAW Cowls1 x Spiral end cap - 80mm1 x 125mm Round 90 Degree Bend1 x HCFT/6-630mm plastic impeller plate fan1 x Purlin Box 500/560 for RAW Cowls1 x Ancillary Pack for SB-CYL 630 model1 x Belt Drive Cased Axial Fan - 630mm - L version1 x Soler & Palau TCBB/6-630/L - IP651 x RVK-EX 315D4 (ATEX) - 315mm Atex Rated Centrifugal Fan1 x JCC-560 - ADAPTER FOR CIRCULAR DUCT - for CTHB/T Roof Fans,1 x Ancillary Pack for SLC-3151 x Elta SLC560/2-3AC - IP551 x Ducting Reducers Short - 315mm-200mm1 x Ducted Outlet Option for H14 - HAP500