• UPC/EAN:0015135093969
  • Model:ACM-100-T

Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan

£ 135.63 (excl. VAT)

£ 162.76 (inc. VAT)

A complete range of energy efficient Mixed Flow In-Line fans that are now quieter than any other product on the market. ACM is now in a range of six products in the range which have been designed for use with rigid and flexible ducting.

In Line Mixed Flow fans offer two and half times the pressure of conventional axial fans, are dimensionally more compact making them ideal for many ducted applications. The impeller blade design with guide vanes provides optimum pressure characteristics and simple connectivity and quieter more efficient running provides the complete solution.

The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions and can be mounted to meet its optimum performance.

ACM 100-200
• Designed and manufactured in UK
• Three speed motor
• Timer versions available
• Removable motor core assembly
• Rotating motor chassis assembly
• IP44 rated
• Aesthetically pleasing with wipe clean polymer casing
• Sound data from independent testing
• Running speed selected on installation
Product Specification
Vent Axia has designed a complete range of energy efficient Mixed Flow In-Line fans that are now quieter, offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions.

Motor
All units have have three speed motors, speed selectable on installation and are fitted with Standard Thermal Overload Protection (S.T.O.P.). Designed for ambient temperatures up to +50°C. All sizes with capacitor run motors. All sizes are Class II appliances. Supply voltage 220-240V/1/50Hz.

Installation
These units have a separate footplate for simple location mounting and detachable spigots for simple connection to ducting. The motor body chassis rotates to provide connection in acute spaces. Cleaning the product has also become simple as all parts can be removed without removing the ducting.

Controller
For optimum variable speed performance use a Vent-Axia 1.5 Amp electronic controller. Surface mounted providing variable speed control with an On/Off/sensor slider with indication light. There is an adjustable minimum speed setting. The controller has electrical connections for use with suitable external sensors. Cannot be used with timer models.

Technical Information
Model - ACM 100T
Airflow - up to 0.085 m/s or 306 m3/hr
Casing - ABS thermoplastic
Speed - 2200 rpm
Airstream Temperature -30°C to 50°C
dBA - 22 dBA @ 3m
Warranty - 2 Years

Electrical Information - 23 Watts
Supply Voltage - 220-240V/1/50Hz
Full Load Current - 0.1 A
Motor - 2 Poles
Insulation - B
Motor IP Rating - IP44
S.T.O.P. Protection - Yes

PDF Files


Catalogue Page

1 x Push Timer Switch - ZA41 x Helios ZNE Electronic Fan Overrun Timer3 x Single phase speed controller by auto-transformer - RMB 1.5 Amp4 x Isolator Switch - ISOSW1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x CS2 Current Switch2 x MWS 3 – Transformer Controller With Motor Protection1 x 7 Day Programmable TIMECLOCK2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x TTC-2000 Three phase electric heater controller2 x COM-33 x Systemair Save Connect 2.0 Internet Module2 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E2 x Elta 6 Amp Electronic single phase speed controller with TK1 x CONTROL ECOWATT - Basic1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp2 x TG-K3/NTC10-01 - Duct temperature sensor2 x Remote Timer Control - 13511 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV1 x Vent Axia ACM 100 inline mixed flow duct fan5 x MWS 1.5 – Transformer Controller With Motor Protection1 x Elta Variable Speed Drive IP66 - 0.75KW2 x Transformer Speed Control - RTRE- 7.0Amp1 x EC-Vent Room Unit4 x WS - Reversing Switch from Helios Fans2 x Isolator Switch - EFF-ISO1 x Silent 100 Window Kit - windowS1 x Multiflow SMB550/4-1AC1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Helios HQW-200/4 - IP552 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted2 x Transformer (silent) speed controller - RE 3.0 Amp2 x PIR Sensor - PIR21 x Electronic extractor fan speed controller - FSC 1.52 x BEAS-control module1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5002 x UB47- Universal Insulated Terminal1 x Envirovent G4 Filter - SL-G4/F71 x Elta 6 Amp Electronic single phase speed controller.2 x Helios HQW-630/4 - IP551 x Transformer Speed Control - RTRE- 12.0Amp1 x REB-CVF 0-10v Controller1 x PIR Sensor - PIR41 x Easy-fix termination kit - High Rise Ventilator - EFT3 x TG-R room temperature sensor1 x Quietflow SQS100-1ECL - Centrifugal Box Fan1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x CBT-100N Centrifugal1 x Vent Axia T-Series Controller1 x Speed Controller - REB12 x AXC TP - 150mm Plastic Centrifugal Inline Fan3 x Vent Axia Silent 100T (TIMER)2 x Vent Axia ACM 150 inline mixed flow duct fan1 x Vent Axia ACM 125 inline mixed flow duct fan1 x CBM 9-9 550w 4P VR (Open Motor)1 x Flakt Woods ME 1.6 speed controller 6.0amp - EA9011591 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x EM30-24 Control Panel Commissioning Service1 x EC6H - Reversible Group Fan Electronic Controller1 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x MTP 10, 10K, Speed control1 x Speed Controller - REB1-N1 x Transformer 5 Speed Controller - ATC1-4TK1 x Two Speed Switch - REGUL-21 x TUNE-R-200-3-M1 - Control Damper1 x Helios HQW-250/4 - IP551 x Vent Axia ACM 200 inline mixed flow duct fan