• Model:EJ411452

40JM/16/4/5/40 - 4Pole - 1PH - Long Cased Axial Fan - EJ411452

£ 757.90 (excl. VAT)

£ 909.48 (inc. VAT)


Flakt Woods 40JM/16/4/5/40 - 4Pole - 1PH - Long Cased Axial Fan - EJ411452

SPECIFICATIONS
Max Airflow: 5,400m3/hr
Motor Power:250W
Motor RPM:1420 rpm
Max Amps :1.6A
Temp Rating: -40°C to +50°C
Weight:28.0Kg

IMPELLER:
BLADE DESIGN: Woods’ AEROFOIL blades incorporate bespoke aerodynamic profiles that are optimised to provide high levels of performance and efficiency with minimal noise generation whilst providing a robust mechanical design.
HUB DESIGN: Profiled hub and clamp-plates are used to retain the blades, whilst permitting blade angle adjustment when the impeller is at rest. Hubs are fitted with an integral steel insert to provide a resilient interface with the motor drive shaft.
STRUCTURAL DESIGN: Impellers are designed with a minimum safety factor of 2.0 when performing within their qualified operating range.
MANUFACTURE: Hub and blade components are precision die cast, or for larger fan diameters, have gravity cast components, using aluminium alloys that have a high levels of strength/weight ratio and provide excellent corrosion resistance. All impeller components undergo real time X-ray inspection to assure structural integrity.
BALANCE: In accordance with ISO 14694, Grade G16 to G2.5, depending on rated motor power.
FORM OF RUNNING: Form B: Airflow through impeller then over the motor (as standard). Form A with airflow over the motor then through the impeller is also available.
IMPELLER LOCATION AND FIXING: Impellers are located on the motor drive shaft by a retaining washer and screw fitted into a tapped hole in the end of the shaft and positively secured with either locking compound or mechanical fixing. Torque transfer is by a key and keyway manufactured in accordance with BS 4235:1972.
NON-OVERLOADING: JM Aerofoil fans have a non overloading characteristic; the peak power input occurs within the range of normal operating pressures and is always exceeded by the motor rating.

FAN CASING
MATERIAL: Casings are manufactured from mild steel to BS EN 10111 Grade DD11.
CASING DESIGN: With integral pre-drilled flanges and fully welded seams. Casing and flange thickness varies depending on fan diameter and motor size. Long cased configurations enclose the entire length of the impeller and motor assembly and are complete with a duct mounted terminal box and inspection port. A rubber moulding is fitted to the port. Short cased configurations where the motor extends beyond the casing are available without a terminal box or sight port. Electrical connection is made directly to the motor.
CASING FINISH: Hot dip galvanised after manufacture to BS EN ISO 1461.
CONNECTION FLANGES: Flanges are an integral part of the fan casing and feature fixing holes that are equi-spaced around a pitch circle diameter to facilitate connection to duct work in accordance with BS EN ISO 13351.

MOTOR
TYPE: Fan motors are of the totally enclosed, squirrel cage induction, S1 continuous duty type.
MOTOR RATINGS: Woods uses integrated fan motors where the ratings are determined in full accordance with IEC 60034-1 when the motor is installed in the fan. Most motors are classed IC 418 according to IEC 60034-6 and therefore cannot be operated when separated from the fan unless a derated TENV rating is applied.
TWO SPEED: Pole Change (also known as PC or Dahlander) motors operate at one of two speeds by reconnecting a single winding via six winding terminals to create the required pole configuration. Dual Wound motors have two separate individual windings of the requisite poles to achieve the required speeds.
ELECTRICAL SUPPLY: Single and three phase motors are available.
220-240 V 60 Hz single phase (1Ø)
400 V 60 Hz three phase (3Ø)
440-480 V 60 Hz three phase (3Ø)
(Other voltages and 50 Hz variants are available on request).
Single phase motors are of the capacitor start and run type. All motors are capable of withstanding direct online starting.
SPEED CONTROL: All three phase, single speed motors are suitable for inverter control. Transformer or electronic control options are also available for some smaller frame sizes.
BEARINGS: Either ball or roller type bearing with an L10 design life of at least 20,000 hours when calculated using ISO 281 for rated fan duty.
MOTOR FINISH: Aluminium self-finish or Cast iron painted to motor manufacturers specification.
INGRESS PROTECTION: IP55 with drain plug fitted.
TERMINAL BOXES: Where fitted, all terminal boxes shall have the same level of protection as the motor.
STANDARD TEMPERATURE FANS: Fans are designed for continuous operation from -40°C to +50°C, with motors suitable for starting at temperatures above -20°C.

PERFORMANCE DATA
Fan performance data is derived from tests conducted in the Woods’ laboratory (accredited by AMCA in accordance with ISO 5801) and is intended for fully ducted, type D configurations.
Acoustic data is derived from tests conducted in the Woods’ laboratory in accordance with ISO 5136 specifically for ducted conditions.
REVERSAL OF AIRFLOW
Woods Air Movement has developed the JM Aerofoil to provide optimum aerodynamic and acoustic performance.
As well as achieving enhanced performance, the development process has established the operational limits of the impellers in all circumstances.
Stress measurements have been conducted when operating in both forwards and reverse modes in order to determine the maximum speeds for continuous operation. This also involved extensive testing of the materials in order to establish relationships between life, operational stresses and casting quality.
Since the stresses experienced in the reverse mode are generally higher than those in forward operation some impeller configurations are not available for reverse operation at maximum speed. In all instances where reverse operation is required, please enquire to confirm suitability.


WARRANTY PERIOD
Our standard warranty period for both the fan and motor is 2 years from date of despatch.
PDF Files


40JM Dimensions


JM Range Specs


JM Wiring info

Available Options

2 x ENV 100 12v transformer SELV1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Mini Diffuser - 100mm2 x ACO8AC/EC AutoChangeover panel2 x RD35S-4DW.6W.3L - 122297 (Three Phase)1 x TUNE-R-200-3-M4 - Control Damper3 x AXC TP - 100mm Plastic Centrifugal Inline Fan1 x 204x60mm Insulated Rectangular Vertical 90° Bend1 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF450/4-1AC - Single Phase1 x Elta Standard Ambient Flexible Connector - 560mm1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x TUNE-R-250-1-M2 - Control Damper1 x Contactor Interface Station - CI91 x TUNE-R-200-3-M2 - Control Damper2 x Silentub - STUB 1001 x Helios RR-250-C Centrifugal inline fan1 x CMT/4-315/130-4KW - Single inlet centrifugal fan direct driven1 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR3 x TUNE-R-315-3-M4 - Control Damper2 x TUNE-R-160-3-M0 - Control Damper (NO ACTUATOR)1 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 736watt CVR1 x CO2 Room Sensor - CO2-R1 x Silent 300 CZ Design PLUS Extractor Fan1 x CMT/4-250-100 1.1KW - Single inlet centrifugal fan direct driven ( LG-90)1 x TUNE-R-200-3-M0 - Control Damper (NO ACTUATOR)3 x 125mm Round Connector with Damper1 x Duct Termination with Mesh - 710mm2 x Speed Controller - REB162 x SPI-100 C Iris damper1 x HIMF - Mixed Flow Fan 100mm Inline Fan2 x Helios HQW-355/4 - IP551 x TUNE-R-100-2-M1 - Control Damper1 x Transformer Speed Control - RTRE- 1.5Amp1 x RDH Flange - 02501 x DDMP 12-12 3F 5700W M6M0 DG71 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven2 x Transformer Speed Control - RTRE- 5.0Amp1 x REB-CVF 0-10v Controller1 x Elta SCP400/4-1AC - IP551 x Speed Controller - REB11 x DDMP 10-10 1F 1000W M6A2 DA52 x Elta Variable Speed Drive IP66 - 2.2KW2 x Biflow SB400-CON2-3 - High Temperature Bifurcated Fan2 x Flanged Damper 019-0560-STD2 x Nicotra RDH G2E7-04501 x SG-400 Fan Guard for flange connection1 x ADH E0-280 Flange - 0280 ADHE/RDHE1 x RDH Flange - 04501 x Elta SPA500/4-1AC - IP541 x SDD-U Anti Vibration Pads2 x ELTA - Single Phase Transformer 8amps1 x DDMP 12-09 1F 1800W M6A4 DA82 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)1 x Control switch - CR1501 x TUNE-R-200-3-M5 - Control Damper1 x Potentiometer EGH 01 - for DDMP Fans2 x Duct Termination with Mesh - 150mm1 x Speed Controller - REB1-N1 x Duct Termination with Mesh - 450mm1 x PM230-TF, AC 230V Damper Actuator, Spring Return, 2 x SPDT, 72C Thermal Fuse1 x Electronic extractor fan speed controller - FSC 1.52 x Run On Timer - 5s - 4hrs - RT5A1 x RDH Flange - 03152 x 110 x 54mm Short Rectangular to Round Adaptor male1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x KBA- Inlet Mounting 1801 x Helios ZNE Electronic Fan Overrun Timer1 x DDMP 12-12 1F 1800W M6A4 DA81 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x VEKA INT 2000/15.0-L1 EKO1 x Helios ESA-1 Surface mounted Speed Control 1amp1 x MWS-75 Transformer controller with TK -7.5A1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Duct Termination with Mesh - 400mm1 x KBA- Inlet Mounting 2251 x Elta 6 Amp Electronic single phase speed controller.1 x Elta SLC500/4B-1AC - IP551 x RR EC 160 Centrifugal inline fan - Energy Efficient Motor1 x ELTA - Three Phase Transformer 10amps1 x Elta SCP500/4-1AC - IP551 x RDH Flange - 04001 x 110 x 54mm Round to Rectangular Adaptor - Long1 x Jetflow Silent SJMF-S 200-1EC1 x TecFire Intumescent Damper - Rectangular 400x400mm1 x TUNE-R-160-3-M2 - Control Damper1 x KBA- Inlet Mounting 2501 x SQUARE MIXED FLOW FAN - MFQ 560mm (Three Phase)
BD7/7 centrifugal M4 0.13Kw
BD7/7 centrifugal M4 0.13Kw
£ 345.00 now £ 300.00
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 132.29

Incredible, Perfect, Silent and Fast delivery ! Thanks "Just...