• Model:RD40

Access Door 400mm x 400mm

£ 34.78 (excl. VAT)

£ 41.74 (inc. VAT)

The Lindab range of RD Series access doors isdesigned to provide rapid access to smoke, fire andvolume control dampers or other equipment mountedinside ductwork or associated plant. All door panels are ofdouble skin construction completely enclosing the 25mmthick high density insulation. Features The RD Series of rectangular doors provide a number of unique advantages:-• All doors are manufactured using C.N.C plant whichensures close fit tolerances and repeatable qualitydoor after door.• Fixing tabs have rounded edges to reduce thepossibility of fitters & inspection engineers sufferingcuts.• Camlocks & strike plates are manufactured from heavygauge steel, zinc plated to prevent twisting anddeformation.• Every door is fitted with two gaskets, one between doorand frame and a second on the back face of the frameto ensure a good seal between frame and ductwork.• High quality gaskets used throughout.• High density insulation.• Independently tested at BSRIA.TechnicalThe RD Series of rectangular access doors have beensuccessfully independently type tested by BSRIA forcompliance to HVCA standard DW144. The products weretested to Class C with a maximum operating pressure of2000 Pa positive and 750 Pa negative.Copies of the complete BSRIA report No 15653/4 areavailable free on request. RD doors comply fully with DW144 specification.Product DataOptions• Stainless steel doors and frames.•50mm thick insulated doors.• Piano hinge on one edge when hinged doors arerequired, product reference RDH.• Safety chain between door and frame, product referenceRDSC.• Other sizes to special order.SpecificationCCL RD doors and frames are manufactured fromcorrosion resistant galvanised steel and fitted with steelzinc plated camlocks and hooks. Gaskets are fitted to bothfaces of the frame.The door panels are filled with high density insulationmaterial.Installation1. Cut a hole in duct 30mm under nominal panel size.2. Ensure that the hole is square and that the duct isadequately stiffened to prevent panting.3. Offer access door subframe into aperture and knockover edge tabs whilst supporting the subframe firmlyonto the duct. Ensure that alltabs are knocked over andthat the sealing gasket is under compression on all facesincluding corners.4.Mount doors into frame and tighten camlocks - do notover tighten.
1 x Elta SCP560/4-3AC - IP551 x Soler & Palau - HCBT/4-560/H - IP651 x Helios HQW-560/4 - IP551 x Elta - HTS450/4-1 - Case Mounted Circulating Axial Fan1 x Access Door for Circular Duct - 400 x 300 - SIZE 631 x 204 x 60mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x Blast Gate (Manual) 300mm1 x Soler & Palau - TGT/4-450-6/0.55kW 32 Degree1 x 125mm Thermal Duct to Fitting Connector - SST-125-DFCON1 x Raptor SDA450/6-1AC1 x Access Door for Circular Duct - 400 x 300 - SIZE 561 x Compact SCD450/4-3AC1 x 100mm Round Wall Plate1 x 125mm Round Wall Plate1 x Blast Gate (Manual) 100mm1 x Soler & Palau - Contra Rotating TCBTx2-450 - IP651 x Access Door for Circular Duct - 300 x 200 - SIZE 351 x 110 x 54mm Short Rectangular to Round Adaptor Female1 x Blast Gate (Manual) 125mm1 x 100mm - 125mm Round Reducer1 x 220x90mm Mounting Clip (Individual)1 x Belt Drive Cased Axial Fan - 450mm - H version1 x Raptor SDA450/4-1EC1 x Access Door for Circular Duct - 280 x 80 - SIZE 101 x 125mm - 100mm Round Reducer1 x Helios VARW 450/4 - TK1 x Anti Vibration Mounts - Small - Pack of 4 - AVM21 x Access Door 400mm x 400mm1 x Helios GigaBox 450mm GBD 450/4/4 centrifugal1 x Access Door for Circular Duct - 400 x 300 - SIZE 451 x 100mm Round Connector1 x 110 x 54mm Rectangular Wall Plate1 x Elta Turboflow-TF - 450mm - Single phase1 x MPC 450 E4 20 - High Temp Acoustic Box Fan1 x Access Door for Circular Duct - 500 x 4001 x Access Door for Circular Duct - 400 x 300 - SIZE 501 x ACCESS DOOR FOR CIRCULAR DUCT 180 X 180 -- 100/125
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 10.53

Look good, works well, except the shaft of the lanellae cuts...