• Model:RD40

Access Door 400mm x 400mm

£ 34.78 (excl. VAT)

£ 41.74 (inc. VAT)

The Lindab range of RD Series access doors isdesigned to provide rapid access to smoke, fire andvolume control dampers or other equipment mountedinside ductwork or associated plant. All door panels are ofdouble skin construction completely enclosing the 25mmthick high density insulation. Features The RD Series of rectangular doors provide a number of unique advantages:-• All doors are manufactured using C.N.C plant whichensures close fit tolerances and repeatable qualitydoor after door.• Fixing tabs have rounded edges to reduce thepossibility of fitters & inspection engineers sufferingcuts.• Camlocks & strike plates are manufactured from heavygauge steel, zinc plated to prevent twisting anddeformation.• Every door is fitted with two gaskets, one between doorand frame and a second on the back face of the frameto ensure a good seal between frame and ductwork.• High quality gaskets used throughout.• High density insulation.• Independently tested at BSRIA.TechnicalThe RD Series of rectangular access doors have beensuccessfully independently type tested by BSRIA forcompliance to HVCA standard DW144. The products weretested to Class C with a maximum operating pressure of2000 Pa positive and 750 Pa negative.Copies of the complete BSRIA report No 15653/4 areavailable free on request. RD doors comply fully with DW144 specification.Product DataOptions• Stainless steel doors and frames.•50mm thick insulated doors.• Piano hinge on one edge when hinged doors arerequired, product reference RDH.• Safety chain between door and frame, product referenceRDSC.• Other sizes to special order.SpecificationCCL RD doors and frames are manufactured fromcorrosion resistant galvanised steel and fitted with steelzinc plated camlocks and hooks. Gaskets are fitted to bothfaces of the frame.The door panels are filled with high density insulationmaterial.Installation1. Cut a hole in duct 30mm under nominal panel size.2. Ensure that the hole is square and that the duct isadequately stiffened to prevent panting.3. Offer access door subframe into aperture and knockover edge tabs whilst supporting the subframe firmlyonto the duct. Ensure that alltabs are knocked over andthat the sealing gasket is under compression on all facesincluding corners.4.Mount doors into frame and tighten camlocks - do notover tighten.
1 x Ducting 30 Degree Bend - 250mm1 x *VORT HRW 40 MONO Evo HCS WIFI - Single Room Heat Recovery Unit,1 x GENIOX 11 Internal Mounted Unit1 x Spigot plate - 250mm1 x CAB-160 ECOWATT Energy Efficient Acoustic Box Fan1 x Spiral Ducting 3 Meters - 150mm1 x Flanged Spigot - 150mm1 x Duct Termination with Mesh - 150mm1 x Acoustic MiniBox Fan - MINI-BOX 1501 x ACQ-150-12D Acoustic Inline Box Fan1 x Duct Suspension Rings - 150mm1 x Anti Vibration Duct Suspension Rings - 150mm1 x Male Ducting Connector - 150mm1 x Female Ducting Connector - 150mm1 x Ducting 90 Degree Bend - 150mm1 x Duct Quick Suspension Rings with Clasp - 150mm1 x AirTrak Heater-315mm1 x HEATER BATTERY+CONTROLS 315 DIA 1 PHASE 4/8kW1 x 220x90mm Insulated Rectangular T-Piece1 x 220x90mm x 2m Insulated Rectangular Duct1 x 220x90mm Elbow Plenum with 160mm Spigot1 x CBMT/Q 400-55 1 HEATER KIT1 x 204x60mm to 125mm Insulated Straight Adapter1 x CBMT/Q 315-30 1 HEATER KIT1 x CBMT/Q 250-54 1 HEATER KIT1 x CBMT/Q 150-15 1 HEATER KIT1 x Access Door for Circular Duct - 300 x 200 - SIZE 351 x Blast Gate (Manual) 180mm1 x Access Door 250mm x 250mm1 x Blast Gate (Manual) 250mm1 x Access Door 450mm x 450mm1 x Access Door for Circular Duct - 300 x 200 - SIZE 401 x ACCESS DOOR FOR CIRCULAR DUCT 180 X 180 -- 100/1251 x Access Door for Circular Duct - 280 x 80 - SIZE 101 x Access Door for Circular Duct - 400 x 300 - SIZE 501 x Small High Temp Gas Blower - FET 3001 x Access Door 400mm x 400mm1 x Access Door for Circular Duct - 500 x 400
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...