• Model:RD40

Access Door 400mm x 400mm

£ 34.78 (excl. VAT)

£ 41.74 (inc. VAT)

The Lindab range of RD Series access doors isdesigned to provide rapid access to smoke, fire andvolume control dampers or other equipment mountedinside ductwork or associated plant. All door panels are ofdouble skin construction completely enclosing the 25mmthick high density insulation. Features The RD Series of rectangular doors provide a number of unique advantages:-• All doors are manufactured using C.N.C plant whichensures close fit tolerances and repeatable qualitydoor after door.• Fixing tabs have rounded edges to reduce thepossibility of fitters & inspection engineers sufferingcuts.• Camlocks & strike plates are manufactured from heavygauge steel, zinc plated to prevent twisting anddeformation.• Every door is fitted with two gaskets, one between doorand frame and a second on the back face of the frameto ensure a good seal between frame and ductwork.• High quality gaskets used throughout.• High density insulation.• Independently tested at BSRIA.TechnicalThe RD Series of rectangular access doors have beensuccessfully independently type tested by BSRIA forcompliance to HVCA standard DW144. The products weretested to Class C with a maximum operating pressure of2000 Pa positive and 750 Pa negative.Copies of the complete BSRIA report No 15653/4 areavailable free on request. RD doors comply fully with DW144 specification.Product DataOptions• Stainless steel doors and frames.•50mm thick insulated doors.• Piano hinge on one edge when hinged doors arerequired, product reference RDH.• Safety chain between door and frame, product referenceRDSC.• Other sizes to special order.SpecificationCCL RD doors and frames are manufactured fromcorrosion resistant galvanised steel and fitted with steelzinc plated camlocks and hooks. Gaskets are fitted to bothfaces of the frame.The door panels are filled with high density insulationmaterial.Installation1. Cut a hole in duct 30mm under nominal panel size.2. Ensure that the hole is square and that the duct isadequately stiffened to prevent panting.3. Offer access door subframe into aperture and knockover edge tabs whilst supporting the subframe firmlyonto the duct. Ensure that alltabs are knocked over andthat the sealing gasket is under compression on all facesincluding corners.4.Mount doors into frame and tighten camlocks - do notover tighten.
1 x Differential Pressure Switch - 50 - 500 Pa - IP541 x CPTA-E Flush mounted PIR sensor with timer1 x Access Door for Circular Duct - 250 x 150 - SIZE 311 x MPC 400 EC T30 - High Temp Acoustic Box Fan1 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan1 x HRST/4-710-20 BPN C Rotorex Sickle bladed fan1 x ZAP 710-63 Plate axial fan1 x Digital Room Thermostat - DRT1 x Differential Pressure Switch - 200 - 1000 Pa - IP541 x EC Trickle and boost module - IP561 x Contactor Interface Station - CI91 x Elta SPA710/6-3EC1 x AES-Fire control unit1 x Air Quality Sensor - AQS1 x DTV200 - Differential Pressure Switch1 x HQD 710/4/4 Plate Axial Fan (2.2kw)1 x EC-Basic-T temperature1 x Soler & Palau - HCBT/4-710/H - IP651 x Spigot plate - 900mm1 x Commercial Thermostat - TH161 x Differential Pressure Switch - 100 - 1000 Pa - IP651 x Curved boot - 900mm1 x HRT/6-710/30-BQ E21 x Soler & Palau - HXTR/6-710/H - IP54 - BFLOW1 x Elta SCP710/4/6-3AC - IP551 x Spiral Ducting 3 Meters - 900mm1 x Ducting 45 Degree Bend - 400mm1 x Ducting 90 Degree Bend - 400mm1 x Spiral Ducting 1 meter - 630mm1 x Elta SPA250/2-1AC - IP441 x Duct Fast Clamps - 400mm1 x 125mm - 150mm Round Reducer1 x Spigot plate - 400mm1 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)1 x Male Ducting Connector - 450mm1 x Belt Drive Cased Axial Fan - 630mm - L version1 x Quietflow SQS500-1ECL - Centrifugal Box Fan1 x Raptor SDA450/4-1AC1 x Singleflow SSDL400-1EC1 x Ducting T Piece Equal - 710mm1 x EBM Papst - W3G910-GU27-03
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...