• Model:RD45

Access Door 450mm x 450mm

£ 40.45 (excl. VAT)

£ 48.54 (inc. VAT)

The Lindab range of RD Series access doors isdesigned to provide rapid access to smoke, fire andvolume control dampers or other equipment mountedinside ductwork or associated plant. All door panels are ofdouble skin construction completely enclosing the 25mmthick high density insulation. Features The RD Series of rectangular doors provide a number of unique advantages:-• All doors are manufactured using C.N.C plant whichensures close fit tolerances and repeatable qualitydoor after door.• Fixing tabs have rounded edges to reduce thepossibility of fitters & inspection engineers sufferingcuts.• Camlocks & strike plates are manufactured from heavygauge steel, zinc plated to prevent twisting anddeformation.• Every door is fitted with two gaskets, one between doorand frame and a second on the back face of the frameto ensure a good seal between frame and ductwork.• High quality gaskets used throughout.• High density insulation.• Independently tested at BSRIA.TechnicalThe RD Series of rectangular access doors have beensuccessfully independently type tested by BSRIA forcompliance to HVCA standard DW144. The products weretested to Class C with a maximum operating pressure of2000 Pa positive and 750 Pa negative.Copies of the complete BSRIA report No 15653/4 areavailable free on request. RD doors comply fully with DW144 specification.Product DataOptions• Stainless steel doors and frames.•50mm thick insulated doors.• Piano hinge on one edge when hinged doors arerequired, product reference RDH.• Safety chain between door and frame, product referenceRDSC.• Other sizes to special order.SpecificationCCL RD doors and frames are manufactured fromcorrosion resistant galvanised steel and fitted with steelzinc plated camlocks and hooks. Gaskets are fitted to bothfaces of the frame.The door panels are filled with high density insulationmaterial.Installation1. Cut a hole in duct 30mm under nominal panel size.2. Ensure that the hole is square and that the duct isadequately stiffened to prevent panting.3. Offer access door subframe into aperture and knockover edge tabs whilst supporting the subframe firmlyonto the duct. Ensure that alltabs are knocked over andthat the sealing gasket is under compression on all facesincluding corners.4.Mount doors into frame and tighten camlocks - do notover tighten.
1 x Male Ducting Connector - 150mm1 x FlameProof Plate Axial Fan - Three Phase - 10.5 inches - Eexd IIC T4 - 4 pole1 x DA 9/7 N2T1 x EBM Papst- A4E 315-AC08-091 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Metal Inline Fan - VENT-200NK1 x Helios AV100 External Wall Fan1 x Acopel F400-250/1601 x Plastic Kitchen Extractors - CK40F1 x CBA-130 Inlet Flange for CBT-1301 x Ducting 45 Degree Bend - 355mm1 x Ancillary Pack for SLC-4006 x Helios HQW-450/6 - IP557 x Access Door for Circular Duct - 400 x 300 - SIZE 401 x DDMP 07/07 Mounting Flange1 x External weather louvre 500w x 500h - WL501 x Elta Cased Axial Flange - 315mm1 x 125mm Wall Duct - 350mm1 x AW Sileo EC Plate Axial Fan - Three Phase - 800mm1 x HRST/6-800/28-BZ-68 (400V50)C1 x HCFT/6-800-H plastic impeller plate fan1 x Chaysol DA 15/11 NT (V72600038) with mounting feet1 x Impeller Side Guard - 450mm1 x Soler & Palau TCBB/4-315/H - IP441 x KMBI 280 Connector rectangular/circular to install on the discharge of CMT1 x KRJ - 160 Inlet Guard for CBB/CBT fans1 x Impeller Side Guard - 350mm1 x Male Ducting Connector - 300mm1 x Soler & Palau - HCBB/4-450/H -IP65 - BFLOW1 x HXP450/4-1 - 4 Pole - Single Phase1 x DDMP 12-12 FLANGE1 x Inclined Kurb support for CTVB/T Fans - BI-51 x HXP450/6-3 - 6 Pole - Three Phase1 x HRB/4-450-35-BPN1 x DDMP12-12 1F 1800W M6A4 DA81 x Hydor HPA450/4-1A1 x FAST-TRACK RANGE 75mm - Semi-Rigid Duct 50M1 x KD 315 L1 - High Performance Duct Fan1 x EM 315-E2M 01- Etamaster-3151 x Remote Indicator RED/GREEN - AM121 x REV-3POL ATEX 11kW-25A ON/OFF1 x Metal Inline Fan - VENT-315NK1 x Remote Fan Status Indicator - RF11 x Ducting Y Piece - 150mm1 x Duct Termination with Mesh - 150mm1 x Female Ducting Connector - 100mm1 x Female Ducting Connector - 150mm1 x MEV300/160 Wireless Boost Switch - SWHWMEV1 x PREP/COOK Switch for use with TCBTx2 PACK's1 x WS - Reversing Switch from Helios Fans1 x Jetflow-HIT Metal inline - 315mm1 x Helios GigaBox 315mm GBW 315/4 centrifugal1 x Flanged Spigot - 150mm1 x Duct Fast Clamps - 150mm1 x MTS10- extractor fan 3 step switch1 x ERR 31/1 Centrifugal inline fan1 x Two Speed Switch - REGUL-21 x Etaline 315mm - D2 01 3 Phase1 x Spigot plate - 150mm1 x Spiral Ducting 1 meter - 150mm1 x Ducting 30 Degree Bend - 150mm1 x Duct Suspension Rings - 150mm1 x Rosenberg RS-315M.3EF Centrifugal Inline Fan1 x Access Door for Circular Duct - 400 x 300 - SIZE 561 x CCpro 40 (1CC9402) Long Casing Extension1 x Access Door for Circular Duct - 300 x 200 - SIZE 311 x Access Door for Circular Duct - 250 x 150 - SIZE 311 x Access Door 250mm x 250mm1 x Circ Outlet spigot for MUB/T Fans - CCM 560mm
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 132.29

Incredible, Perfect, Silent and Fast delivery ! Thanks "Just...