• Model:RD45

Access Door 450mm x 450mm

£ 46.72 (excl. VAT)

£ 56.06 (inc. VAT)

The Lindab range of RD Series access doors isdesigned to provide rapid access to smoke, fire andvolume control dampers or other equipment mountedinside ductwork or associated plant. All door panels are ofdouble skin construction completely enclosing the 25mmthick high density insulation. Features The RD Series of rectangular doors provide a number of unique advantages:-• All doors are manufactured using C.N.C plant whichensures close fit tolerances and repeatable qualitydoor after door.• Fixing tabs have rounded edges to reduce thepossibility of fitters & inspection engineers sufferingcuts.• Camlocks & strike plates are manufactured from heavygauge steel, zinc plated to prevent twisting anddeformation.• Every door is fitted with two gaskets, one between doorand frame and a second on the back face of the frameto ensure a good seal between frame and ductwork.• High quality gaskets used throughout.• High density insulation.• Independently tested at BSRIA.TechnicalThe RD Series of rectangular access doors have beensuccessfully independently type tested by BSRIA forcompliance to HVCA standard DW144. The products weretested to Class C with a maximum operating pressure of2000 Pa positive and 750 Pa negative.Copies of the complete BSRIA report No 15653/4 areavailable free on request. RD doors comply fully with DW144 specification.Product DataOptions• Stainless steel doors and frames.•50mm thick insulated doors.• Piano hinge on one edge when hinged doors arerequired, product reference RDH.• Safety chain between door and frame, product referenceRDSC.• Other sizes to special order.SpecificationCCL RD doors and frames are manufactured fromcorrosion resistant galvanised steel and fitted with steelzinc plated camlocks and hooks. Gaskets are fitted to bothfaces of the frame.The door panels are filled with high density insulationmaterial.Installation1. Cut a hole in duct 30mm under nominal panel size.2. Ensure that the hole is square and that the duct isadequately stiffened to prevent panting.3. Offer access door subframe into aperture and knockover edge tabs whilst supporting the subframe firmlyonto the duct. Ensure that alltabs are knocked over andthat the sealing gasket is under compression on all facesincluding corners.4.Mount doors into frame and tighten camlocks - do notover tighten.
1 x HIMF - Mixed Flow Fan 125mm Inline Fan2 x MV-Silent 350 Bathroom Extractor Fan Kit - Timer1 x 125mm - 100mm Round Reducer1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Elta Variable Speed Drive IP66 - 7.5KW1 x Elta Variable Speed Drive IP66 - 2.2KW1 x FRQ5-10A Inverter Speed controller1 x FU 15 16 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Frequency converter RUCK - FU 075 201 x Elta Variable Speed Drive IP66 - 4.0KW1 x Frequency converter FU 075 14 - IP661 x Elta Variable Speed Drive IP66 - 0.75KW1 x FU 22 25 Frequency Inverter1 x FU 075 52 Frequency Inverter (IP20)1 x FRQ5-4A V2 Inverter Speed Controller1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x FU 075 04 Frequency Inverter (IP20)1 x Frequency converter RUCK - FU 075 211 x FU 22 04 Frequency Inverter1 x Frequency converter RUCK - FU 075 381 x Elta 10 Amp Electronic single phase speed controller.1 x ELTA - Three Phase Transformer 10amps1 x ELTA - Single Phase Transformer 2amps1 x EC6H - Reversible Group Fan Electronic Controller1 x Elta 3 Amp Electronic single phase speed controller.1 x Elta 6 Amp Electronic single phase speed controller with TK1 x EFSC-3N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 8amps1 x ELTA - Single Phase Transformer 16amps3 x Airvent ceiling fan controller1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x ELTA - Single Phase Transformer 4amps1 x COM-31 x Elta 6 Amp Electronic single phase speed controller.1 x Elta Variable Speed Drive IP66 - 0.75KW (1ph to 3ph)1 x EFSC-6N- Single Phase Speed Control1 x Elta Variable Speed Drive IP66 - 1.5KW (1ph to 3ph)1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Push Timer Switch - ZA41 x Helios ZNE Electronic Fan Overrun Timer1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x REE-2 Electronic Speed Controller1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x EM30-24 Electro-Mechanical Control Panel1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x ACO 149-ACO1/EDV1 x Vent Axia ACM 125 inline mixed flow duct fan1 x EC-Vent Room Unit1 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x EM30-24 Control Panel Commissioning Service2 x 204x60mm Insulated Rectangular Horizontal 90° Bend1 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC25/311 x Elta Wall Cowl SWC35/401 x Elta Wall Cowl SWC45/501 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x Jet Cowl - 315mm1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Egg Crate Grille with Dust panel filter 1 inch- 595x5951 x Single Deflection Grille 400mm with OBD damper1 x Universal Pipe Fixing Clip1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x Same Day Shipping Surcharge - City Sprint1 x Northern Ireland Pallet Surcharge1 x Elta - SMT 125 Mixvent Inline Fan - Clearance Stock Line1 x Transformer speed controller - ATC1 - 1.5 Amps
Reviews
Airvent Ceiling Sweep Fan - 36 inch - 444122
Airvent Ceiling Sweep Fan - 36 inch - 444122
£ 59.84

Fitted 2 Of These Excellent Fans in a Community Club to shif...