• Model:ACOAS-ADS-VFC

ACOAS-ADS-VFC - Automatic Duty Share Changeover panel

£ 143.00 (excl. VAT)

£ 171.60 (inc. VAT)

The ACOAS changeover panels are designed to suit single phase twin fan units with airflow switches. Please note that an airflow switch must be fitted to monitor each fan and the airflow switches must not “see” the airflow from the other fan I.E. the 2 airflow switches cannot be in the same airstream.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have fail contacts that can be used in conjunction with a remote indicator or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x 110 x 54mm Rectangular Wall Plate1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Elta 10 Amp Electronic single phase speed controller.1 x Balance S Diffuser - NO RING - 125mm1 x Circular Ceiling Diffuser - TST 1251 x ELTA - Single Phase Transformer 2amps1 x NKS-D swirl diffuser v-300 x 300mm1 x Circular Ceiling Diffuser - TST 1602 x Helios TSW MCB Amp Transformer speed controller1 x Elta 2 Amp Electronic single phase speed controller.2 x Helios TSW 10 Amp Transformer speed controller1 x JSR 200 Painted RAL50181 x Round ceiling diffuser 400mm1 x Curved Blade Grille 600x600 (2way blow)1 x Circular Ceiling Diffuser - TST 2001 x EC6H - Reversible Group Fan Electronic Controller1 x Circular Ceiling Diffuser - TST 1001 x Electronic extractor fan speed controller - FSC 1.51 x PCA Diffuser - PCA-3151 x ELTA - Single Phase Transformer 4amps1 x Round ceiling diffuser 300mm1 x AIRVENT speed control - AIR4019611 x Round ceiling diffuser 200mm1 x ELTA - Single Phase Transformer 12amps1 x Balance S Diffuser - NO RING - 100mm1 x Elta 3 Amp Electronic single phase speed controller.1 x Elta 6 Amp Electronic single phase speed controller with TK1 x EFSC-3N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 16amps1 x ELTA - Single Phase Transformer 8amps1 x Airvent ceiling fan controller1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Round ceiling diffuser 350mm1 x Elta 6 Amp Electronic single phase speed controller.1 x PCA Diffuser - PCA-2501 x EFSC-6N- Single Phase Speed Control1 x Round ceiling diffuser 250mm1 x Remote Timer Control - 1351