• Model:ACOFR9A-ADS-VFC

ACOFR9A-ADS-VFC - Automatic Duty Share Changeover panel

£ 139.00 (excl. VAT)

£ 166.80 (inc. VAT)

The ACOFR changeover panels are designed to suit single phase twin fan units where airflow switches are not fitted.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have run and fail contacts that can be used in conjunction with remote indicators or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT560/4-3AC1 x DV-ROF-V-315 Roof mounted unit1 x Spiral Ducting 1 meter - 180mm1 x MEV Spider Additional Spigots1 x Elta Wall Cowl SWC45/501 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF315/4-1AC - Single Phase1 x Elta SLC1000/4C-3AC - IP551 x Belt Drive Cased Axial Fan - 800mm - L version1 x Elta Wall Cowl SWC25/311 x CRHB-250N Ecowatt - Energy Efficient Roof Fan1 x Belt Drive Cased Axial Fan - 900mm - H version1 x Elta LC100N4-A6/381 x Curved boot - 180mm1 x Frequency converter RUCK - FU 075 201 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 400mm1 x Biflow SB315-CON2-3 - High Temperature Bifurcated Fan1 x FN091-SDK.6N.V7P21 x Ducting 90 Degree Bend - 180mm1 x Economy Airvent 100mm Fan with Timer/Humidistat/Pullcord1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x Belt Drive Cased Axial Fan - 800mm - H version1 x Elta Raptor SFB ATEX Plate Mounted Axial Fan- 420mm1 x Spiral Ducting 3 Meters - 150mm1 x Ducting 45 Degree Bend - 125mm1 x Hydor HPA250/2-11 x Spiral Duct Grille Termination - 150mm1 x Elta Raptor SFB ATEX Plate Mounted Axial Fan- 560mm1 x Raptor SDA500/4-3EC1 x HCF - Ceiling Fan 1400mm (56 inch)1 x Belt Drive Cased Axial Fan - 630mm - H version1 x 100mm Round Connector1 x ACOFR9A-ADS-VFC - Automatic Duty Share Changeover panel1 x Ducting 90 Degree Bend - 800mm1 x Flanged Spigot - 80mm1 x HRT/4-630/25-BPN C1 x 220x90mm Elbow Bend with 125mm Fixed Spigot1 x Curved boot - 800mm1 x Three Phase ATEX Compact axial fan - 315mm - compactATEC41 x Female Ducting Connector - 800mm
Air Quality Sensor - AQS
Air Quality Sensor - AQS
£ 98.29 now £ 65.00
Reviews
Vectaire Elegance Low Energy DMEV Fan Range
Vectaire Elegance Low Energy DMEV Fan Range
£ 119.00

I've had 2 of these fans for 4 years now, and they are great...