• Model:ACOFR9A-ADS-VFC

ACOFR9A-ADS-VFC - Automatic Duty Share Changeover panel

£ 139.00 (excl. VAT)

£ 166.80 (inc. VAT)

The ACOFR changeover panels are designed to suit single phase twin fan units where airflow switches are not fitted.
The control panel fascia has a power lamp, fan fail lamp and a rocker switch. The VFC models have run and fail contacts that can be used in conjunction with remote indicators or to interface with a building management system.

Installation:
Check that the auto changeover panel supplied is compatible with the fan motors. Install in a dry sheltered position. Do not install in close proximity to a heat source. Remove the front cover of the controller by unscrewing the fascia fixing screws. This provides access to mounting holes and electrical terminals. All wiring must be carried out by a suitably qualified and competent person and comply with current applicable regulations.

Auto Changeover:
The control panel will automatically changeover from the duty fan to the standby fan if the fuse (within the auto changeover panel) for the duty fan ruptures.
Manual duty share models:
Manual duty share models are fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan as described in Auto Changeover above.
Auto duty Share models:
Auto duty share models are fitted with an electronic timer to provide a 12 hour cycle time for each fan.The timer has a jumper link to allow testing of the auto changeover on a 1 minute test cycle for each fan. After testing the jumper link should be fitted back in the 12hr cycle time position. The position of the jumper link for the test cycle and 12 hour cycle are shown below.
Volt free contacts (VFC models)

These models are suffixed with VFC and feature 2 sets of volt free contacts, 1 set for a common fan run status and 1 set for a common fan fail status. The contacts are normally open and close when either fan is running or has failed.
PDF Files


Data Sheet

1 x Male Ducting Connector - 315mm1 x BDRAX 250-E2 Cased Axial External Rotor Fan1 x Impeller Side Guard - 630mm1 x FSAF400B1DA Silencer 450/81 x Duct Fast Clamps - 315mm1 x FSAF1250C1DA Silencer 1320/201 x Elta Unpodded Silencer 1D-500mm1 x Access Door for Circular Duct - 300 x 200 - SIZE 401 x Elta Unpodded Silencer 1D-560mm1 x Quietflow SQSDCV400-1ECL - Centrifugal Box Fan1 x KRJ - 225 Inlet Guard1 x Blast Gate (Manual) 300mm1 x Flanged Spigot - 315mm1 x Helios AV150 External Wall Fan1 x Impeller Side Guard - 560mm1 x FSAF355B1DX Silencer 395/81 x Access Door for Circular Duct - 400 x 300 - SIZE 451 x KVK Slim 400 - Low profile Semi Acoustic Box Fan1 x Air Quality Sensor - AQS1 x Ducting 45 Degree Bend - 80mm1 x BFR 100-160 Coarse 50% Filter1 x Raptor SDA560/46-3AC1 x Elta SLC560-1EC -IE5 Motor- IP551 x 2mtr Insulated Round Ducting - 125mm1 x Elta - SMT 125 Mixvent Inline Fan - Clearance Stock Line1 x DS-2 2-Speed Switch (3 Phase)1 x Female Ducting Connector - 80mm1 x 316 Grade Stainless Steel Flat Bar Flange - 400mm1 x GB-WSD 500 Weather Protection hood for the Giga-Box Fans - 500mm1 x Motorised Volume Control Damper - 400mm1 x Control with reverse - CR3001 x Elta Turboflow-TF - 560mm - Single phase1 x Duct Mounted Filter Box - 450mm - M6 grade Bag filter1 x Duct Mounted Filter Box - G4 Grade Panel - 125mm1 x Elta Cased Axial Flange - 315mm1 x 56Jm/16/4/5/32/1Ph Long cased axial1 x DV-ROF-V-315 Roof mounted unit1 x HD Series Control Damper - 2300mm X 1000mm1 x CBA-80 Inlet Flange for CBT-801 x DV-ROF-V-225 Roof mounted unit1 x SPI-150 C Iris damper1 x 220x90mm Insulated Rectangular Horizontal 45° Bend1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 4501 x MPS Weather Housing1 x Duct Mounted Filter Box - G4 Grade Panel - 150mm1 x KABT/4- 9000/500