• Model:ERM18EXE

Atex Inline Fan 180mm - ERM18EXE

£ 937.13 (excl. VAT)

£ 1,124.56 (inc. VAT)

Product description
* For commercial use: Durable, powerful and robust.
* Type-examination tested according to European Directive 94/9/EC (ATEX).
* Device group II, Category 2 G
* Type of protection "e": Increased safety
* For zones 1 and 2.
* For ventilation or air extraction, depending on the installation direction.
* Can be fitted in any position.
* Balanced safety technology available.
* 310m3/hr this version
Features
* MAICO Ex fans fulfil the safety requirements of European Directive 94/9/EC for units and protective systems in explosion-endangered areas.
* Device group II, Category 2 G
* Type of protection "e": Increased safety
* For zones 1 and 2.
* Supply of smaller air volumes only at medium resistances.
* Housing and impeller are made from high quality synthetic material, antistatic
* Semi-centrifugal impeller, favourable flow technology.
* Inflow direction equals outflow direction. Thus resulting in simple installation.
* Can be fitted in any position.

Air flow direction
* Airstream and rotational directions are indicated by arrows marked on the fan housing

Motor
* Robust motor with ball bearings, maintenance-free.
* Capacitor motors with operating capacitor ready for use in terminal box.

Mounting instructions
* Inlet and outlet side connection couplings for direct installation in ventilation ducts.
* Reducers for connecting to different duct diameters (intake or exhaust sockets); see Accessories.
* Use ELM-Ex flexible cuffs to prevent transfer of vibrations onto the duct system.
* ERM 22 E Ex e: 2 reducers to DN 200 included in scope of delivery.

Electrical connection
* Terminal box fitted to fan housing, explosion proof.

Required safety technology
* MVEx motor safety switch to monitor the maximum motor current.
* Accessories needed for ERM...E Ex e.
* Type-examination tested according to Directive 94/9 EC (ATEX).
* Installation exclusively in non-explosive areas.

Safety instructions
* No speed control allowed.
* The fan may only be operated using the rated voltage shown on the rating plate.
* The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 294 for fans with free inlet and outlet. To do this, fit an SGR-Ex protective grille.
* Ensure that foreign bodies cannot fall into or be sucked into the fan.

PDF Files


ERM-18 Datasheet

1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x EC-Vent control board1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x EC-Vent Room Unit2 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B2 x EM30-24 Control Panel Commissioning Service1 x D2E-146-AP47-752 x Multi Input Run On Timer - 0 - 20min - CFCU2 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x Helios TSW MCB Amp Transformer speed controller1 x Helios TSW 1.5 Amp Transformer speed controller2 x Vent Axia ACM 125 inline mixed flow duct fan2 x TG-K Duct temperature sensor1 x Two Speed Switch - REGUL-21 x Electronic extractor fan speed controller - FSC 1.53 x Transformer (silent) speed controller - RE 3.0 Amp1 x Transformer (silent) speed controller - RE 5.0 Amp1 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x Speed Controller - REB1-N1 x MTS10- extractor fan 3 step switch1 x Speed Controller - REB11 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x PIR Sensor - PIR21 x PIR Sensor - PIR41 x SAVE VSR 300 heat recovery unit1 x VEKA INT 2000/15.0-L1 EKO1 x EBM-Papst D3G133-BF05-14 Double inlet1 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x IR24-P - Presence detector1 x VTR 500 STD Filter Kit1 x Round ceiling diffuser 250mm1 x ACO3TO-ADS-VFC-7.1A1 x DDMP 07/07 Mounting Flange1 x KRJ - 120 Inlet Guard for CBB/CBT fans1 x MEV Spider Additional Spigots1 x SDD-U Anti Vibration Pads1 x Elta SCP315/4-1AC - IP551 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Transformer 5 Speed Controller - ATC1-12TK1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Isolator Switch - ISOSW1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x DEF-140T Inlet Guard for the CBT-100N1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x 7 Day Programmable TIMECLOCK1 x ERR 20/1 Centrifugal inline fan1 x Remote Timer Control - 13511 x Helios HQW-630/4 - IP551 x CBS-60 Outlet Flange for CSB/CBT-601 x TG-K3/NTC10-01 - Duct temperature sensor1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Speed Controller - REB51 x Speed Controller - REB101 x Transformer Speed Control - RTRE- 5.0Amp1 x Transformer Speed Control - RTRE- 7.0Amp1 x Transformer Speed Control - RTRE- 1.5Amp1 x ELM 25 EX Flexible Cuff for ERM 251 x MTP 10, 10K, Speed control1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x TD Mixvent 800/200 EEXEIIT3
BD7/7 centrifugal M4 0.13Kw
BD7/7 centrifugal M4 0.13Kw
£ 345.00 now £ 300.00
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...