• Model:BIFA-630-2/3

Bifurcated Long Cased Axial Fan - 630-2-3ph

£ 3,653.93 (excl. VAT)

£ 4,384.72 (inc. VAT)

The Bifurcated Case Axial range of fans has been specifically developed to meet the need for an axial fan which can handle atmospheres normally detrimental to the life of the fan motor.

By isolating the motor from the system airstream, the bifurcated fan can handle a wide variety of saturated and dustladen atmospheres, heated air and hot gases.

The range has a split airway with adirect driven motor operating in ambient air within the motor compartment. They are suitable, as standard, for handling air temperatures up to +200°C.

The Bifurcated Case Axial Fan range has a number of accessories available which include: Axial Ancillary Pack, Attenuator, Wire Inlet Guard, Coupling Flanges, Mounting Feet, AV Mounts and Speed Controllers.

Motor

The motors are specially selected to operate within the motor compartment with the airstream in the duct system, at an elevated temperature.

Motors are of the B3 foot mounting type, totally enclosed and fan cooled. Being foot mounted the motors can, in the event of a failure, be readily interchanged with a comparable frame size from a wide range of manufacturers to cover temperatures of up to 200°C.

Where indicated, the motor is suitable for speed control by either an inverter or a 5-step auto transformer speed controller when the ambient air temperature is not higher than 60ËšC.

Electrical

Single phase 220-240V 50 Hz supply are available in 5 sizes:-250, 315,400,450 and 500mm diameter. 250 to 400 diameter in either 2 or 4 pole versions, 500mm diameter in 4 pole. Three phase 380-440V 50Hz supply are available in eleven sizes 250, 315, 400, 450, 500, 560, 630 in either 2 or 4 pole versions (710, 800, 900 and 1000 dia are available as 4 pole).

Impellers and Casing
The aluminium alloy impellers are die cast and have an adjustable pitch which allows a wide range of air outputs to be selected. All the casings are manufactured in steel and hot dipped galvanised to BS EN ISO 1461 after fabrication. Motor mountings and fixings used in the assembly of the fan are zinc plated and passivated.

Form of Running
Bifurcated fans have arrows showing the direction of the impeller rotation and airflow. All models are Form B running.

Terminal Box
To IP55, protected against dust and water jets from any angle, allowing outside applications.

Performance
Tested to BS 848 Part 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5Pa (20 micro-Pascal). The inlet and outlet sound power level spectra figures are dB with a reference of 10-12 Watts (1 pico-watt).

Cooling
External cooling is provided by a fan mounted at the non-drive end of the motor, protected by a cover with a grid air intake. The airflow, guided by the fan cover, is directed longitudinally on the entire periphery of the motor in the channels formed by the frame ribs.

Adequate space is provided within the motor compartment to ensure a plentiful supply of cooling air. The air within the motor compartment must not exceed 40ËšC. For ambients in excess of this, please consult our Technical Services Department for further information.
PDF Files


Data Sheet

1 x Ducting Reducers Short - 315mm-250mm1 x Direct Delivery Surcharge1 x Duct Mounted Filter Box - G4 Grade Panel - 150mm1 x Helios GigaBox 250mm EC - GBW 250 EC T120 centrifugal1 x CC-SHT 804 A T 5,5Kw F4001 x KRJ - 355 Inlet Guard1 x Differential Pressure Switch - 50 - 500 Pa - IP651 x Belt Drive Cased Axial Fan - 710mm - H version1 x ELTA - Single Phase Transformer 12amps1 x Duct Mounted Filter Box - G4 Grade Panel - 200mm1 x Ancillary Pack for SB-CYL 630 model1 x CO2 Room Sensor - CO2-R1 x Belt Drive Cased Axial Fan - 450mm - L version1 x Traditional T-Series Wall Fan - TX12WL1 x Galvanised Banding1 x Anti Vibration Duct Suspension Rings - 125mm1 x Spiral Ducting 1 meter - 150mm1 x KBR/F 315D2 sm ext F4001 x CHGT/4-800-9/-7.5KW- AXIAL FLOW CABINET FANS1 x Elta SCP560/4-1AC - IP551 x Pulser Temperature control1 x CPTA-E Flush mounted PIR sensor with timer1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-1000-B 5.5kw1 x CC-SHT 1004 (7.5kw)1 x CHGT/4-630-6/-3KW- AXIAL FLOW CABINET FANS1 x Impeller Side Guard - 250mm1 x Impeller Side Guard - 560mm1 x KRJ - 225 Inlet Guard1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 400mm1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-900-B 5.5kw1 x Impeller Side Guard - 350mm1 x Access Door for Circular Duct - 400 x 300 - SIZE 631 x Spiral Ducting 3 Meters - 500mm1 x TG-K3/NTC10-01 - Duct temperature sensor1 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x Bifurcated Fan - TET 4/4001 x AXC 355-6/19°-2(B)-P (0.75 kW) - Smoke Extract Fan1 x EC-Basic-T temperature1 x EC Trickle and boost module - IP561 x JBS-1250 Flat Roof Upstand for HCTT/4-1000/B1 x CC-SHT 504 (C-Version)1 x Chimney Smoke & Flue Gas Fans - ZRS1 x DTV200 - Differential Pressure Switch1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT350/4-3AC1 x IR24-P - Presence detector1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT400/4-3AC
Air Quality Sensor - AQS
Air Quality Sensor - AQS
£ 98.29 now £ 65.00
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 125.99

Unbelievable! With TDmixvent500: noise reduction minimum 50%...