• Model:CADB-HE-D08

CADB/T-HE PRO-REG Series

£ 5,194.01 (excl. VAT)

£ 6,232.81 (inc. VAT)

This unit is Model:CADB-HE-D 08 RH PRO-REG VE

Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised steel in white. Panels are double skinned with thermo-acoustic flameproof insulation (M0), made from 25mm thick fiberglass in false ceiling versions (Models 04 to 33 ) and 47mm in outdoor versions (Models 45 and 60).
Configurable and airtight supply and exhaust spigots, suitable for horizontal and vertical installation.
Minimum outdoor temperature -10ºC. For lower temperatures it is necessary to use preheating batteries located in the suction of the outside air.

Applications
Commercial premises, offices, restaurants, public buildings, schools.
CADB/T-HE D PRO-REG

Heat recovery units without additional incorporated heater.

CADB/T-HE DC PRO-REG
Heat recovery units with built-in hot water coil.
The 3-Way valve is provided as an accessory (see accessories table for this series)

CADB/T-HE DI PRO-REG
Heat recovery units with built-in electric heater battery.

Motors
Models 04 to 21: EC motors with integrated electronic protection, IP44, Class B.
Models 33 to 60: EC motors with integrated electronic protection, IP 54 class B.

Fans
Plug-fan with backward curved impeller.

Filters
- F7: Low pressure F7 filters for supply air.
- M5: M5 filters for extract air.
- Possibility of mounting a second filter (accessory). It is possible to complement the heat recovery unit with a specific range of water and direct expansion coils. Also available, the exclusive module IAQ with high efficiency VOCs and particles filtration that guarantees the filtration and purification of the outdoor air.

Control
It includes manual or automatic control for modes: adjustable airflow (VAV), constant pressure (COP) or constant airflow (CAV), via CO2, pressure or airflow sensors (accessories).
Post-heating stage versions (-DC/-DI) allow postheating management depending on the temperatures taken by the temperature probes incorporated in the design.

Ranges of product according to the type of operating control:
VAV- variable air volume
Fan speed can be adjusted with a 0 - 10V signal from the remote touchscreen panel (included) or an external CO2, temperature or humidity sensor (accessories).
CAV - constant air volume
Manual pre-setting of 2 working points the fans are controlled separately, regardless of the degree of fouling of the filters. It is necessary to add two pressure sensors TDP-S as external accessory.
COP - constant pressure
Constant pressure measured by an external pressure sensor TDP-S (accessory). It is necessary to add a pressure sensor TDP-S as an external accessory*.
* To control supply and extract air separately it is necessary to install 2 pressure sensors TDP-S.

Additional information
Single phase (CADB-HE PRO-REG) and three phase models (CADT-HE PRO-REG).
Airflows from 450 to 6100 m3/h at 150 Pa of static pressure available.
All versions and models include by-pass.
Mounting flexibility provided by the interchangeable side panels.
1 x Helios TSD 3.0 Transformer Speed Control (400v)1 x FU 15 40 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 7.5KW1 x Elta Variable Speed Drive IP66 - 2.2KW1 x Elta Variable Speed Drive IP66 - 5.5KW1 x FU 15 16 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Frequency converter RUCK - FU 075 201 x Elta Variable Speed Drive IP66 - 4.0KW1 x Frequency converter FU 075 14 - IP661 x FU 22 25 Frequency Inverter1 x FU 075 52 Frequency Inverter (IP20)1 x FRQ5-4A V2 Inverter Speed Controller1 x FRQ-10A V2 Inverter Speed controller1 x FU 22 04 Frequency Inverter1 x Frequency converter RUCK - FU 075 211 x FU 075 04 Frequency Inverter (IP20)1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x Elta 10 Amp Electronic single phase speed controller.1 x ELTA - Three Phase Transformer 10amps1 x ELTA - Three Phase Transformer 3amps1 x ATEX rated 3-phase Speed Control - R-DK4 KT (EX)1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x FRQ5-10A Inverter Speed controller1 x ELTA - Single Phase Transformer 2amps1 x NKS-D swirl diffuser v-300 x 300mm1 x Electronic extractor fan speed controller - FSC 1.51 x Circular Ceiling Diffuser - TST 1251 x Balance S Diffuser - NO RING - 125mm1 x Curved Blade Grille 600x600 (2way blow)1 x EC6H - Reversible Group Fan Electronic Controller1 x Circular Ceiling Diffuser - TST 1001 x PCA Diffuser - PCA-3151 x Elta 3 Amp Electronic single phase speed controller with TK1 x JSR 200 Painted RAL50181 x Round ceiling diffuser 400mm1 x Elta 2 Amp Electronic single phase speed controller.1 x Circular Ceiling Diffuser - TST 2001 x Elta 3 Amp Electronic single phase speed controller.1 x EFSC-3N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 16amps1 x ELTA - Single Phase Transformer 8amps1 x Circular Ceiling Diffuser - TST 1601 x Airvent ceiling fan controller1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Round ceiling diffuser 200mm1 x AIRVENT speed control - AIR4019611 x Balance S Diffuser - NO RING - 100mm1 x COM-31 x ELTA - Single Phase Transformer 12amps1 x EFSC-6N- Single Phase Speed Control1 x Round ceiling diffuser 300mm1 x ELTA - Single Phase Transformer 4amps1 x Elta 6 Amp Electronic single phase speed controller.1 x Round ceiling diffuser 250mm1 x PCA Diffuser - PCA-2501 x Round ceiling diffuser 350mm1 x ELTA - Single Phase Transformer 10amps1 x Run On Timer - 5s - 4hrs - RT5A1 x Remote Timer Control - 13511 x REU 7amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Push Timer Switch - ZA41 x Helios ZNE Electronic Fan Overrun Timer1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x 7 Day Programmable TIMECLOCK1 x TTC-2000 Three phase electric heater controller1 x Helios TSW 0.3Amp Compact Transformer speed controller1 x REB-CVF 0-10v Controller
BD9/9 centrifugal M4 0.35Kw
BD9/9 centrifugal M4 0.35Kw
£ 399.00 now £ 350.00
Reviews
TD-SILENT 350/125
TD-SILENT 350/125
£ 178.68

Excellent low noise fan, I've got one unit running years and...