• Model:443319L

Lo-Carbon Sentinel Kinetic BH - LEFT

£ 1,199.00 (excl. VAT)

£ 1,438.80 (inc. VAT)

Lo-Carbon Sentinel Kinetic BH Left

* Recognised in SAP PCDB
* Lightweight for easier installation
* Horizontal duct option for space-saving installations
* Fits within a 290mm deep kitchen cupboard
* Integrated digital controller for simple and accurate commissioning
* Plug and play control; Humidistat
* BMS connectivity
* LS inputs (Light Switch)
* Horizontal duct options
* Acoustic Enclosure & Top Box options

Stock Ref. No: 443319L

Easy Installation
The Sentinel Kinetic models can be mounted vertically in a roof space, hallway cupboard or kitchen or within a kitchen cupboard. When mounted in an unheated area ducting and MVHR unit should be insulated. Ducting can be attached to the unit horizontally, vertically or both. Minimum internal depth of kitchen cupboard: V, B & BH models 290mm.

For scenarios where noise is a critical issue, an Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies.

Left (L) or right (R) hand installation. The unit is supplied with duct spigots to outside on the right hand side. These can be reversed on site by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel.

Spigot Options
The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom ofthe unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.

Integral Humidity Sensor (BH Models)
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.

Acoustic Solution

PDF Files


Data Sheet

1 x NKS-D swirl diffuser v-300 x 300mm1 x Circular Ceiling Diffuser - TST 1251 x Balance S Diffuser - NO RING - 125mm1 x PCA Diffuser - PCA-3151 x Round ceiling diffuser 400mm1 x Curved Blade Grille 600x600 (2way blow)1 x Circular Ceiling Diffuser - TST 2001 x Circular Ceiling Diffuser - TST 1601 x JSR 200 Painted RAL50181 x Round ceiling diffuser 200mm1 x Balance S Diffuser - NO RING - 100mm1 x Round ceiling diffuser 300mm1 x Round ceiling diffuser 250mm1 x PCA Diffuser - PCA-2501 x Round ceiling diffuser 350mm1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Helios ZNE Electronic Fan Overrun Timer3 x Push Timer Switch - ZA41 x Time Delay Unit - DT20B2 x Multi Input Run On Timer - 0 - 20min - CFCU1 x 7 Day Programmable TIMECLOCK1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel1 x EC-Vent Room Unit2 x Systemair Save Connect 2.0 Internet Module1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Elta ACO Panel 149-ACO18B1 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Elta 10 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 2amps2 x Electronic extractor fan speed controller - FSC 1.52 x EC6H - Reversible Group Fan Electronic Controller2 x Vent Axia ACM 150 inline mixed flow duct fan1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Elta 2 Amp Electronic single phase speed controller.1 x Elta 3 Amp Electronic single phase speed controller with TK2 x Elta 6 Amp Electronic single phase speed controller with TK1 x ELTA - Single Phase Transformer 8amps1 x EFSC-3N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 16amps1 x Airvent ceiling fan controller1 x Elta 3 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 12amps1 x COM-31 x AIRVENT speed control - AIR4019611 x ELTA - Single Phase Transformer 4amps1 x EFSC-6N- Single Phase Speed Control1 x Elta 6 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 10amps2 x MWS 3 – Transformer Controller With Motor Protection2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x Helios TSW 3 Amp Transformer speed controller1 x Helios TSW MCB Amp Transformer speed controller1 x Helios TSW 10 Amp Transformer speed controller3 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x Isolator Switch - ISOSW2 x BEAS-control module3 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan3 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Helios TSW 0.3Amp Compact Transformer speed controller2 x Remote controller FLEX - for VEKO INT1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x WS - Reversing Switch from Helios Fans2 x Transformer 5 Speed Controller - ATC1-10TK2 x Transformer 5 Speed Controller - ATC1-4TK2 x Transformer 5 Speed Controller - ATC1-8TK1 x Transformer 5 Speed Controller - ATC1-12TK2 x Vent Axia ACM 125 inline mixed flow duct fan1 x CS2 Current Switch1 x TG-K Duct temperature sensor
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...