• Model:DVG-V560D4I

DVG-V 560D4/F400 IE2

£ 1,954.68 (excl. VAT)

£ 2,345.62 (inc. VAT)

DVG-V 560D4/F400 IE2Smoke Extract Roof Fan
The DVG smoke extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation.

Smoke-free escape ways increase the chances to rescue people in case of fire.
The casing is manufactured from seawater resistant aluminium. The base frame consists of galvanised steel. The impeller with backward-curved blades is manufactured from galvanised steel. Motor outside air stream is cooled with fresh air.

• Smoke and heat extract unit + normal ventilation
• Up to 400°C / 120 min (F400/120, F400/90, F300, F200)
• Normal ventilation up to 120°C continuous operation
• Vertical exhaust
• Service switch serial
• Suitable for coastal applications
• Wide range of accessories
• Tested acc. to EN 12101-3 at LGAI, Barcelona
• CE-certified acc. to EN 12101-3, 2002-06 at TÜV Süd
The DVG smoke extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation.

Smoke-free escape ways increase the chances to rescue people in case of a fire. For installation only on top of heated buildings.

The casing is manufactured from seawater resistant aluminium. The base frame consists of galvanised steel. The impeller with backward-curved blades is manufactured from galvanised steel.

Motor outside air stream is cooled with fresh air. Thermal motor protection on request (PTC or thermal contact). For frequency controlled units PTC must be ordered. For two speed fans (up to 4 kW) two speed switch is available as accessories (in this case thermal contact must be ordered; not suitable for PTC or without thermal contact). In case of fire eventual two speed switch, frequency inverter and all protective devices must be bridged to guarantee functional capability (connection direct to mains). At frequency controlled units additional EMC protection could be needed (on request).

Note (for EU market only): not affected by efficiency provisions of Commision Regulation (EU) No 327/2011 - exception 3 (c) (i) (a)
1 x Elta SCP500/4-3AC - IP551 x Ducting 90 Degree Bend - 355mm1 x HRB/4-450-35-BPN1 x Male Ducting Connector - 800mm1 x Ancillary Pack for SLC-4001 x ZAC- 630 -4-31 x Soler & Palau - TGT/4-450-6/0.55kW 32 Degree1 x Elta 10 Amp Electronic single phase speed controller.1 x NKS-D swirl diffuser v-300 x 300mm1 x Circular Ceiling Diffuser - TST 1251 x ELTA - Single Phase Transformer 2amps1 x Balance S Diffuser - NO RING - 125mm1 x PCA Diffuser - PCA-3151 x Electronic extractor fan speed controller - FSC 1.51 x Circular Ceiling Diffuser - TST 2001 x Circular Ceiling Diffuser - TST 1001 x Curved Blade Grille 600x600 (2way blow)1 x EC6H - Reversible Group Fan Electronic Controller1 x Round ceiling diffuser 400mm1 x Circular Ceiling Diffuser - TST 1601 x 5-Speed Controller for use with Elta SAX Classic Fans2 x Elta 6 Amp Electronic single phase speed controller with TK1 x ELTA - Single Phase Transformer 16amps1 x Balance S Diffuser - NO RING - 100mm1 x EFSC-3N- Single Phase Speed Control2 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta 3 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 8amps1 x Round ceiling diffuser 200mm1 x Airvent ceiling fan controller1 x ELTA - Single Phase Transformer 12amps1 x AIRVENT speed control - AIR4019611 x ELTA - Single Phase Transformer 4amps1 x Round ceiling diffuser 300mm3 x COM-31 x Round ceiling diffuser 250mm1 x Round ceiling diffuser 350mm1 x EFSC-6N- Single Phase Speed Control1 x Elta 6 Amp Electronic single phase speed controller.1 x PCA Diffuser - PCA-2501 x ELTA - Single Phase Transformer 10amps1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Helios ZNE Electronic Fan Overrun Timer3 x Push Timer Switch - ZA41 x Time Delay Unit - DT20B2 x Multi Input Run On Timer - 0 - 20min - CFCU1 x 7 Day Programmable TIMECLOCK1 x TTC-2000 Three phase electric heater controller1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan2 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans2 x Vent Axia ACM 150 inline mixed flow duct fan1 x Helios TSW 7.5 Amp Transformer speed controller1 x Helios TSW 0.3Amp Compact Transformer speed controller1 x RTRD - Three Phase Speed Controller - 2 Amp3 x Transformer 5 Speed Controller - ATC1-12TK2 x Helios TSW 3 Amp Transformer speed controller3 x Systemair Save Connect 2.0 Internet Module3 x Three Phase Transformer controllers - RMT 1.5 Amp2 x Vent Axia ACM 100 inline mixed flow duct fan1 x Helios TSW MCB Amp Transformer speed controller1 x Helios TSW 1.5 Amp Transformer speed controller3 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan2 x Remote controller FLEX - for VEKO INT2 x Transformer 5 Speed Controller - ATC1-4TK2 x Transformer 5 Speed Controller - ATC1-10TK1 x Transformer 5 Speed Controller - ATC1-8TK1 x Envirovent 4 Way Remote Control Switch - SWHBKRF-42 x MWS 3 – Transformer Controller With Motor Protection1 x DEF-140T Inlet Guard for the CBT-100N1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp3 x Vent Axia ACM 125 inline mixed flow duct fan2 x CS2 Current Switch2 x Isolator Switch - ISOSW1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x TG-K Duct temperature sensor2 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x Helios HQW-200/2 - IP551 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Elta ACO Panel 149-ACO18B2 x BEAS-control module1 x Envirovent G4 Filter - SL-G4/F71 x WS - Reversing Switch from Helios Fans2 x MWS 1.5 – Transformer Controller With Motor Protection