• Model:149-ACO18B

Elta ACO Panel 149-ACO18B

£ 451.53 (excl. VAT)

£ 541.84 (inc. VAT)

Elta ACO Panel 149-ACO18B

A range of auto changeover controllers for use with AC or EC single or three phase twin fans

• Run & Standby
• Automatic Changeover in the event of fan fail
• Duty Share Option
• Remote Enable Option
• VFC Fail Contact Option

Twin Fan Control
Run and Standby operation ensures ventilation in the event of one fan failing by automatically running the second fan.

Duty Share (option on three phase)
Duty share provides even wear on both fans and extending fan life by sharing fan operating time between the two fans.

Remote Enable (option on three phase)
Remote enable contact allows the ventilation to be switched off from a remote source ensuring energy is not wasted at periods where no ventilation is required.

Speed Control
Suitable for use with remote speed controllers to adjust fan speeds to ventilation demand saving energy and maintaining thermal comfort.

Motor Protection
With built-in motor protection the ACO Panel provides safe disconnection from the power supply in the event of a fan fail while allowing operation of the second fan to maintain ventilation.

AC/EC Single Phase Specification
The ACO18B Auto Changeover Panel as supplied by Elta shall provide Run and Standby operation of AC or EC single Phase twin fans.

Remote activation shall be via a set of volt free contacts.

Duty Share between fan 1 and fan to shall be selected via a jumper terminal with set time adjustment intervals from 3 hours to 24 hours in 3-hour steps.

Individual volt free contacts for each fan shall be available that switch on with the activation of the corresponding fan; This can be used for enabling extra-low or low voltage up to 230 volts with a maximum current of 8 amps.

Fan fail detection shall be via Tacho output, relay or airflow detection.

BMS output remote fault shall be indicated by an individual set of contacts capable of a maximum controlling load up to 230 volts at 8 Amps.

Manual speed control shall be available from the speed potentiometer on the board or the option of a secondary control. Whichever of these has the highest setting takes priority. A time delay shall exist on fault detection at fan startup or fan changeover over to prevent nuisance fail signals.

AC Three Phase Specification
The ACO3 ranges of Auto Changeover Panels as supplied by Elta Fans shall provide Run and Standby operation of AC Three Phase twin fans.

The changeover panels shall incorporate industrial contactors fitted with thermal overloads pre-set to requirements. The control panel fascia shall have a power lamp, fan fail lamp and a rocker switch. Speed controllers of AC Electronic or Transfer type shall be suitable for remote connection.
The control panel shall automatically changeover from the duty fan to the standby fan if the thermal overload trips or on loss of airflow detected by airflow switches (if airflow switches are fitted to the twin fan unit).

ACO3/B model shall be fitted with a 2-position (Fan A/Fan B) rocker switch enabling the user to manually select the duty fan. The control panel will auto changeover from the duty fan to the standby fan in the event of fan fail.

ACO3/BDV models shall incorporate an electronic timer to provide a 12-hour cycle time for each fan. The timer shall have a jumper link to allow testing of the auto changeover on a 1-minute test cycle for each fan. A Common Volt Free Contact shall be provided for remote fan fail indication.

1 x 204x60mm Insulated Rectangular Horizontal 45° Bend1 x 220x90mm Insulated Rectangular Vertical 90° Bend1 x Transformer Speed Control - RTRE- 1.5Amp1 x 204x60mm Insulated Rectangular Vertical 45° Bend1 x MTS10- extractor fan 3 step switch3 x CBM 12-12 1100w 6P Three Phase1 x Elta - Room Sensor - Temp/Humid/C022 x 204x60mm Insulated Rectangular Vertical 90° Bend1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Duct Termination with Mesh - 355mm3 x DEF-CBM-RE-7 - Protection Guard4 x CBA-100 Inlet Flange for CBT-1004 x SPI-100 C Iris damper3 x CBT-100N Centrifugal1 x CK-60F Kit2 x VTR 300 STD Filter Kit3 x Helios ESA-1 Surface mounted Speed Control 1amp2 x SD-MUB Vibration pad set1 x Singleflow SSDL315-1EC2 x WSD 100 (1060x1060x70)1 x AIRVENT speed control - AIR4019611 x Electrostatic Precipitator - 1H x 3W2 x CBT-130N Centrifugal ATEX II 3D ExtD 125*C1 x Contactor Interface Station - CI91 x TUNE-R-200-3-M0 - Control Damper (NO ACTUATOR)1 x Vertical Cowl and Fan (Single Phase) - RAV400-4-13 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x CO2 Room Sensor - CO2-R2 x CFI In-line 150 - Carbon Filter2 x Helios RR-250-C Centrifugal inline fan3 x SAVE VSR 300 heat recovery unit1 x Silentub - STUB 1003 x Helios HQW-355/4 - IP551 x Duct Termination with Mesh - 100mm1 x DA9/9-NT2 x Comefri - TLZ 450 R - High Performance Scroll Fan2 x ACO8AC/EC AutoChangeover panel1 x VTR 500 STD Filter Kit1 x Flakt Woods ME 1.6 speed controller 6.0amp - EA9011593 x 100mm Round Connector with Damper1 x DS-2 2-Speed Switch (3 Phase)1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Round ceiling diffuser 200mm3 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 736watt CVR1 x CSB-60 Centrifugal fan1 x Round ceiling diffuser 250mm3 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR2 x Elta SCP400/4-1AC - IP551 x TD160-NT Mixvent - 100mm - TD160 Timer1 x Binks Bullows - Spray Booth Filter1 x Flakt Woods ME 1.1 speed controller 1amp - EA9011572 x DDMP 12-12 3F 5700W M6M0 DG71 x IR24-P - Presence detector2 x Duct Termination with Mesh - 150mm1 x KBA- Inlet Mounting 2252 x Flat Roof Terminal -OFT 5 - Asphalt1 x KAD-225-F400 Rectangle Flexible Connector1 x Flakt Woods ME 1.3 speed controller 3amp - EA9011581 x Mini Diffuser - 100mm1 x ACO3TO-ADS-VFC-7.1A1 x LFBR 160 G4 - Helios Inline Filter Box - 160mm1 x RD35S-4DW.6W.3L - 122297 (Three Phase)1 x DDMP 10-10 1F 1000W M6A2 DA51 x HIMF - Mixed Flow Fan 125mm Inline Fan1 x TUNE-R-200-3-M2 - Control Damper1 x CCpro 40 (1CC9402) Long Casing Extension1 x CBB-60N Centrifugal1 x Duct Termination with Mesh - 450mm1 x CBS-100 Outlet Flange for CBT-1001 x Potentiometer EGH 01 - for DDMP Fans1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x TD Mixvent 1100/250 EEXEIIT31 x DDMP 07/07 Mounting Flange1 x Quietflow Twin SQTDCV250-1ECL1 x CAD-COMPACT 900 ADVANCED N8 - MVHR unit1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)2 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan1 x Elta Variable Speed Drive IP66 - 0.75KW1 x RUCK MTP 20, 10K, Speed control1 x Helios ZNE Electronic Fan Overrun Timer1 x VEKA INT 2000/15.0-L1 EKO