• Model:SQT125-1ECL

Elta Quietflow Twin SQT125-1ECL

£ 1,656.27 (excl. VAT)

£ 1,987.52 (inc. VAT)

Elta Quietflow Twin SQT125-1ECL

Each unit is acoustically lined internally with Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining minimising breakout noise levels.
New Multi-mount brackets allow easy mounting in a range of orientations.
Integrated commissioning control allowing single speed selection and also limiting maximum speed if used with an external potentiometer.
High efficiency low tonal noise backward curved centrifugal impellers are directly driven by EC external rotor motors, provide low specific fan powers and stepless speed control without tonal noise generation.
Units can be weatherproofed in the factory to allow external installation.
EC motors providing precise speed control via potentiometer, BMS or Elta Fans DCV control. Reduced fan speeds can provide significant cost-savings through lower energy consumption in both mechanical energy of motors and also on the conditioning of replacement air.
Twin Fan Operation
Allowing control for auto changeover and duty share.
Each SQT has a 12 month warranty.
The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motormounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning.
The twin range of units have an EC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. All motors are suitable for use in ambient air conditions up to +60 ℃. Electrical connection shall be via an IP55 terminal box mounted on the side for easy customer connection.
High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO 14694 Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit.
Units shall be supplied with integrated commissioning control allowing single speed selection and also limiting maximum speed if used with an external potentiometer. Speed control shall be via external potentiometer or0-10V, Auto changeover in the event of fan fail or duty share of run and standby fan shall be via auto changeover panel which is an optional extra.
Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001. All Quietflow SQT units are to be tested to ISO 5801 (airside performance) and BS 848 Part 2 (sound performance).
PDF Files


Data sheet

1 x 125mm Round Connector1 x Spiral Ducting 1 meter - 125mm1 x TTT/4-560/L N 0,75KW (230/400V50HZ)EXEIIT3 VE Atex Unit1 x Female Ducting Connector - 560mm1 x H14 Hepa Commercial Air Purifier - Coarse Filter1 x Acopel F400-280/1601 x EMI 150L E2M - Acoustic Inline Mixvent Fan1 x FAST-TRACK RANGE 75mm - Straight Connector1 x Balance S Diffuser - NO RING - 125mm1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x Egg Crate Grille with Dust panel filter 1 inch- 595x5951 x Single Deflection Grille 400mm with OBD damper1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Mini Diffuser - 100mm1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x Circular Ceiling Diffuser - TST 1602 x RTRD - Three Phase Speed Controller - 2 Amp1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW 1.5 Amp Transformer speed controller2 x Vent Axia ACM 150 inline mixed flow duct fan1 x Helios TSW 7.5 Amp Transformer speed controller1 x Remote controller FLEX - for VEKO INT2 x Transformer 5 Speed Controller - ATC1-12TK2 x Temperature Fan Speed Controller - ATCP4-WMS1 x Helios TSW 0.3Amp Compact Transformer speed controller1 x Vent Axia ACM 125 inline mixed flow duct fan1 x MV-B Dual Switch for use with Helios HQW plate fans,1 x CS2 Current Switch1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Vent Axia ACM 100 inline mixed flow duct fan1 x MWS 3 – Transformer Controller With Motor Protection1 x Helios TSW 3 Amp Transformer speed controller2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven2 x Elta 6 Amp Electronic single phase speed controller with TK1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x DEF-140T Inlet Guard for the CBT-100N1 x Helios HQW-200/2 - IP551 x MWS 1.5 – Transformer Controller With Motor Protection1 x RDS 7 Helios Transformer Controller With Motor Protection1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp2 x Helios TSW MCB Amp Transformer speed controller2 x Helios TSW 10 Amp Transformer speed controller1 x WS - Reversing Switch from Helios Fans1 x ERR 20/1 Centrifugal inline fan1 x Two Speed Switch - REGUL-21 x Helios HQW-630/4 - IP552 x CBS-60 Outlet Flange for CSB/CBT-601 x Insulated extract Plenum 8+11 x Insulated extract Plenum 6+11 x Transformer (silent) speed controller - RE 3.0 Amp1 x Helios HQW-200/4 - IP551 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x ERR 31/1 Centrifugal inline fan1 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x Electronic extractor fan speed controller - FSC 1.51 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x Transformer (silent) speed controller - RE 1.5 Amp1 x 7 Day Programmable TIMECLOCK1 x Multiflow SMB550/4-1AC1 x Remote Timer Control - 13511 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Speed Controller - REB51 x Vent Axia ACM 200 inline mixed flow duct fan1 x Isolator Switch - ISOSW1 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x KKS 100 silencer-section - For use with the MUB 100 size Fans.1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Push Timer Switch - ZA41 x Airvent ceiling fan controller
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 44.99

Well made and robust, but it was not use for my application ...