• Model:FSD-TD180

FSD-TD 180mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)

£ 385.00 (excl. VAT)

£ 462.00 (inc. VAT)

FSD-TD Features and Benefits

• Tested and certified installation variants of the FSD-TD are available to cover masonry walls, dry walls, batt walls and floors. These cover the majority of applications/supporting constructions that are required to maintain compartmentation and protect escape routes and areas with sleeping risk.
• All BSB tested installation methods give at least a ES120 (E120S) classification, usually only limited by the wall construction used. This is extended to 4 hours when installed using a HEVAC frame in a masonry/blockwork floor or wall.
• Sleeve and angle methods, HEVAC frame methods, angle frame methods, cleat and drop rod methods and batt infill methods are available. • Some rarer installation applications are covered by assessment/test information to BS 476-20/22.
• Minimum size 100 x 100 (not adapted from a larger size by reducers) available for space saving.
• Circular connection - base damper does not increase, thus saving space and transport volume.
• Single section size up to 1000 x 1000 in millimetre increments.
• Multi-section configurations are available to specific customer requirements, but will be subject to Building Control Authority approval.
• No duct sleeve, again giving space savings over other models and savings on transport volume.
• Standard construction is a fully welded galvanised steel case, which gives a casing leakage that complies with Class C ductwork leakage specifications.
• Blades have folded safe-edges to aid site safety.
• Galvanised mild steel DX 51D Z275, Ferritic (430) type 1.4016 or Austenitic (316) 1.4401 grade stainless steels for the blades and case are available for specific customer requirements.
• All blade and motor connecting drives are removed from the airstream and are fully enclosed. This gives both increased free area through the damper and protection to the mechanisms.
• Electrical Actuators (24VAC/DC, 230VAC,) have a less than 60 second motoring time. They have multi-position fitting and, being remote from the duct, allow space savings.
• All damper/actuator assemblies are mechanically tested prior to despatch (NOTE: The thermal fuse needs to be fitted/installed through the duct wall by the customer when the damper is installed).
• Actuators may be supplied separately to the dampers for site fitting by others to suit customer specific requirements.
• The FSD-TD range is fully compatible with the BSB range of smoke control panels, fire alarm systems, building management systems (BMS) and other bespoke control systems.
• The BSB FSD-TD has a strong and robust design to both meet the exacting fire testing requirements and be resilient to site handling. This is supported by sound production techniques which result in a quality product.
• All the above, supported with BSBs enviable delivery performance, provide an unbeatable combination.
1 x Duct Mounted Filter Box With G2 Paper AND Metal Washable Filter - 150mm1 x HRB/4-500-30-APNC1 x Duct Mounted Filter Box - G4 Grade Panel - 400mm1 x 100mm Round 90 Degree Bend1 x Duct Mounted Filter Box - MINICELL F7 Grade Panel Filter 250mm Spigot1 x CBM 12/9 750W RE-VR1 x Soler & Palau TCBT/6-400/H - IP441 x HXP500/4-1 - 4 Pole - Single Phase1 x BDB 630 TL D50 VE - High Pressure Centrifugal Fan1 x EnergiSava 210 Low Energy Heat Recovery Unit1 x HCFB/4-500mm plastic impeller plate fan1 x HRT/4-500/25-BPN C1 x Raptor SDA400/4-1AC1 x 100mm Round Wall Plate1 x Duct Mounted Filter Box - G4 Grade Panel - 100mm1 x Genius Whole house unit -1 x Duct Mounted Filter Box - G4 Grade Panel - 250mm1 x Soler & Palau TCBT/4-400/H - IP441 x Helios HQW-500/4 - IP551 x AKOR T3/7 Spare Motor1 x CBM 12/9 515W RE-VR1 x Curved boot - 710mm1 x Flanged Spigot - 300mm1 x ACO3/BD Changover Panel (Three Phase)1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 6 Pole 300watt VR RE1 x Curved boot - 300mm1 x Ducting Reducers Long - 300mm-250mm1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT500/4-3AC1 x AxZent 400 D2 High Temp Kitchen exhaust Fan1 x CHVB/4-3000/315 0,27KW 230V50 VE1 x Elta Podded Silencer 1D- 710mm1 x Hydor HPA450/6-1A1 x Elta Unpodded Silencer 1D-500mm1 x Hydor Typhoon Circulation Fans - HVFB - 300mm1 x Elta SCP450-1EC - IP551 x Ducting T Piece Equal - 300mm1 x Spigot plate - 400mm1 x HCFT/4-450mm plastic impeller plate fan1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-900-B 5.5kw1 x Centrifugal Roof Mounted Fans MAX-TEMP CTVB / CTVT Series - Vertical Discharge1 x FSAF355B2DX Silencer 395/81 x Elta Podded Silencer 2D- 710mm1 x Airvent Ceiling Sweep Fan - 56 inch - 4441241 x FSD-TD 400 x 250 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x ACO3TO-ADS-VFC-7.1A