• Model:FSD-TD300200

FSD-TD 300 x 200 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM24-TF (SC)

£ 446.25 (excl. VAT)

£ 535.50 (inc. VAT)

FSD-TD Features and Benefits

• Tested and certified installation variants of the FSD-TD are available to cover masonry walls, dry walls, batt walls and floors. These cover the majority of applications/supporting constructions that are required to maintain compartmentation and protect escape routes and areas with sleeping risk.
• All BSB tested installation methods give at least a ES120 (E120S) classification, usually only limited by the wall construction used. This is extended to 4 hours when installed using a HEVAC frame in a masonry/blockwork floor or wall.
• Sleeve and angle methods, HEVAC frame methods, angle frame methods, cleat and drop rod methods and batt infill methods are available. • Some rarer installation applications are covered by assessment/test information to BS 476-20/22.
• Minimum size 100 x 100 (not adapted from a larger size by reducers) available for space saving.
• Circular connection - base damper does not increase, thus saving space and transport volume.
• Single section size up to 1000 x 1000 in millimetre increments.
• Multi-section configurations are available to specific customer requirements, but will be subject to Building Control Authority approval.
• No duct sleeve, again giving space savings over other models and savings on transport volume.
• Standard construction is a fully welded galvanised steel case, which gives a casing leakage that complies with Class C ductwork leakage specifications.
• Blades have folded safe-edges to aid site safety.
• Galvanised mild steel DX 51D Z275, Ferritic (430) type 1.4016 or Austenitic (316) 1.4401 grade stainless steels for the blades and case are available for specific customer requirements.
• All blade and motor connecting drives are removed from the airstream and are fully enclosed. This gives both increased free area through the damper and protection to the mechanisms.
• Electrical Actuators (24VAC/DC, 230VAC,) have a less than 60 second motoring time. They have multi-position fitting and, being remote from the duct, allow space savings.
• All damper/actuator assemblies are mechanically tested prior to despatch (NOTE: The thermal fuse needs to be fitted/installed through the duct wall by the customer when the damper is installed).
• Actuators may be supplied separately to the dampers for site fitting by others to suit customer specific requirements.
• The FSD-TD range is fully compatible with the BSB range of smoke control panels, fire alarm systems, building management systems (BMS) and other bespoke control systems.
• The BSB FSD-TD has a strong and robust design to both meet the exacting fire testing requirements and be resilient to site handling. This is supported by sound production techniques which result in a quality product.
• All the above, supported with BSBs enviable delivery performance, provide an unbeatable combination.
1 x Gorilla HVLSX401 x 220x90mm to 160mm straight adapter1 x EBM Papst - W3G910-GU27-031 x Ducting 30 Degree Bend - 450mm1 x QP315C Acoustic Fan - 315mm1 x 100mm Round Wall Plate1 x Universal Pipe Fixing Clip1 x 150mm Round Connector1 x Flanged Spigot - 80mm1 x 100mm Wall Duct - 350mm1 x Classic SAX23/9A Window/Wall Mounted1 x 220x90mm x 2m Insulated Rectangular Duct1 x 204 x 60mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x Classic SAX23/9AR Window/Wall Mounted1 x 220 x 90mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x 220x90mm Insulated Rectangular Vertical 90° Bend1 x 204x60mm Insulated Rectangular Horizontal 90° Bend1 x Classic SAX30/12ARB Wall Mounted1 x 220x90mm Insulated Rectangular Horizontal 90° Bend1 x Classic SAX23/9ARB Wall Mounted1 x Elta HWFA-650 Oscillating Wall Fan1 x 125mm Thermal Duct to Duct Connector - SST-125-DDCON1 x 220 x 90mm Duct to Fitting Connector for use with Insulated Thermal Ducting1 x Classic SAX30/12AR Window/Wall Mounted1 x 204x60mm x 1m Insulated Rectangular Duct1 x 204x60mm Insulated Rectangular Vertical 90° Bend1 x Gorilla HVLSX301 x Classic SAX30/12A Window/Wall Mounted1 x CBMT/Q 250-54 1 HEATER KIT1 x DT-1 Duct Mounted Thermostat1 x VKS 355-500 Automatic shutter1 x Soler & Palau - HCBB/4-450/H -IP65 - BFLOW1 x DHS 450DV roof fan1 x Digital Room Thermostat - DRT1 x CVAT Acoustic Kitchen Fan & Inverter Kit - CVAT/6-15000/710 ND - Pack 101 x KABT High Temp Acoustic Kitchen Fan & Inverter Kit - KABT/4-6000/450 ND - Pack 31 x TD1000 Mixvent - 250mm1 x AMD 225/4 - Medium pressure axial fan 3-PH 400 V1 x Elta SLC500/2A-3AC - IP551 x Helios HRFW 500/41 x Duct Fast Clamps - 200mm1 x Spiral Ducting 3 Meters - 400mm1 x FSD-TD 225mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x CBM 12/9 736W 6PT C - Closed Motor1 x Ducting T Piece Equal - 355mm1 x Spiral Duct Grille Termination - 315mm1 x FSD-TD 400 x 200 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...