• Model:FSD-TD350

FSD-TD 350mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)

£ 495.00 (excl. VAT)

£ 594.00 (inc. VAT)

FSD-TD Features and Benefits

• Tested and certified installation variants of the FSD-TD are available to cover masonry walls, dry walls, batt walls and floors. These cover the majority of applications/supporting constructions that are required to maintain compartmentation and protect escape routes and areas with sleeping risk.
• All BSB tested installation methods give at least a ES120 (E120S) classification, usually only limited by the wall construction used. This is extended to 4 hours when installed using a HEVAC frame in a masonry/blockwork floor or wall.
• Sleeve and angle methods, HEVAC frame methods, angle frame methods, cleat and drop rod methods and batt infill methods are available. • Some rarer installation applications are covered by assessment/test information to BS 476-20/22.
• Minimum size 100 x 100 (not adapted from a larger size by reducers) available for space saving.
• Circular connection - base damper does not increase, thus saving space and transport volume.
• Single section size up to 1000 x 1000 in millimetre increments.
• Multi-section configurations are available to specific customer requirements, but will be subject to Building Control Authority approval.
• No duct sleeve, again giving space savings over other models and savings on transport volume.
• Standard construction is a fully welded galvanised steel case, which gives a casing leakage that complies with Class C ductwork leakage specifications.
• Blades have folded safe-edges to aid site safety.
• Galvanised mild steel DX 51D Z275, Ferritic (430) type 1.4016 or Austenitic (316) 1.4401 grade stainless steels for the blades and case are available for specific customer requirements.
• All blade and motor connecting drives are removed from the airstream and are fully enclosed. This gives both increased free area through the damper and protection to the mechanisms.
• Electrical Actuators (24VAC/DC, 230VAC,) have a less than 60 second motoring time. They have multi-position fitting and, being remote from the duct, allow space savings.
• All damper/actuator assemblies are mechanically tested prior to despatch (NOTE: The thermal fuse needs to be fitted/installed through the duct wall by the customer when the damper is installed).
• Actuators may be supplied separately to the dampers for site fitting by others to suit customer specific requirements.
• The FSD-TD range is fully compatible with the BSB range of smoke control panels, fire alarm systems, building management systems (BMS) and other bespoke control systems.
• The BSB FSD-TD has a strong and robust design to both meet the exacting fire testing requirements and be resilient to site handling. This is supported by sound production techniques which result in a quality product.
• All the above, supported with BSBs enviable delivery performance, provide an unbeatable combination.
1 x ELTA - Single Phase Transformer 8amps1 x 204x60mm to 220x90mm Rectangular Adapter1 x 204x60mm Flat Channel Clip (Pack of 5)1 x Electronic extractor fan speed controller - FSC 1.51 x 204x60mm 45 Degree Horizontal Bend1 x ELTA - Single Phase Transformer 4amps1 x Helios AV125 External Wall Fan1 x 204x60mm Elbow Bend with 100mm Fixed Spigot1 x 204x60mm x 1000mm Long Hi-Flow Duct Silencer1 x *VORT HRW 30 MONO Evo - Single Room Heat Recovery Unit,1 x Elta 3 Amp Electronic single phase speed controller.1 x Genius Whole house unit -1 x Elta Variable Speed Drive IP66 - 1.5KW (1ph to 3ph)1 x Duct Fast Clamps - 100mm1 x Digital Room Thermostat - DRT1 x HCGT/2-315/L-AMXN E7201 x Ducting 30 Degree Bend - 200mm1 x Elta Turboflow-TF - 630mm - Single phase1 x FSD-TD 400 x 250 Fire and Smoke Damper, S, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x Ducting 15 Degree Bend - 150mm1 x Soler & Palau TCBT/6-630/L - IP651 x Ducting Y Piece - 150mm1 x HCFT/4-630mm plastic impeller plate fan1 x Male Ducting Connector - 200mm1 x Elta SPA450/46-3AC - IP541 x HXP450/4-3 - 4 Pole - Three Phase1 x FSD-TD 250mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)1 x HXP450/6-1 - 6 Pole - Single Phase1 x Remote Timer Control - 13511 x Vent Axia SABRE Plate Mounted Sickle Fans - VSP315141 x EBM Papst W3G630-GG97-011 x Spiral Duct Grille Termination - 150mm1 x Compact SCD630/4-3AC1 x Spiral Rapid Lock Clamp - 250mm1 x KV DUO 315 EC1 x Duct Suspension Rings - 250mm1 x Ducting 90 Degree Bend - 150mm1 x Spiral Ducting 1 meter - 150mm1 x Duct Quick Suspension Rings with Clasp - 150mm1 x Soler & Palau - HCBB/2-355/H - IP651 x Ducting 45 Degree Bend - 150mm1 x MELL-USD 700 Rectangular to Circular Adaptor 150 Dia1 x Spigot plate - 250mm1 x Male Ducting Connector - 150mm1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x MPC 450 E4 20 - High Temp Acoustic Box Fan1 x Ancillary Sealing Band - 250mm1 x Push Timer Switch - ZA41 x FSD-TD 225mm Fire and Smoke Damper, Type C, EASY FIX AF, GALV Case, GALV Blades, PM230-TF (SC)