• Model:HR200WK

HR200WK single room heat recovery unit

£ 719.18 (excl. VAT)

£ 863.02 (inc. VAT)

A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x KVK SLIM 355 EC - Centrifugal Circular Duct Fan1 x Chaysol SA 18/8 RTC CW-single inlet centrifugal fan1 x MELL-USD 700 Rectangular to Circular Adaptor 150 Dia1 x CMB-2-140-050 0.25Kw LG O1 x Mellizo 700 EcoWatt - Twin Fan - 150mm1 x Quietflow Twin SQTDCV250-1ECL1 x SAVE VTC 200 L High efficiency Heat Recovery Unit1 x GEO Ground Source Heat Exchanger1 x SAVE VTR 500 L Heat Recovery Unit1 x 7 Day Programmable TIMECLOCK1 x Carriage1 x Roof Axial Cowl - RAW10001 x Kitchen Grease Filter - Mesh Type Non standard 450mm x 150mm x 22mm ( CEF450 Replacement)1 x Kitchen Grease Filter - Mesh Type NON standard 195H x 597W x 47mm Actual1 x Soler & Palau VFD-T inverter 5 amp IP541 x Ducting 90 Degree Bend - 250mm1 x Spiral Ducting 3 Meters - 125mm1 x Quietflow Twin SQTDCV125-1ECL1 x CMT-2 250-100 3KW - LG0 Single inlet centrifugal fan direct driven1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x Quietflow Twin SQTDCV500-1ECL1 x CMT/4-315/130-4KW - Single inlet centrifugal fan direct driven1 x CMRT/2-451 7,51 x CMB-2-160-060 0.37Kw1 x CMT-2 250-100 3KW - RD270 Single inlet centrifugal fan direct driven1 x Quietflow Twin SQTDCV400-1ECL1 x CMT-2 280/115 4KW - Single inlet centrifugal fan direct driven1 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven1 x CMT-2 180/75 0.75KW - Single inlet centrifugal fan with inlet and outlet flange connections - 200mm1 x CMT-2 160-60 0.37KW - LG270 Single inlet centrifugal fan direct driven1 x CMT/4-280-115 2.2KW - Single inlet centrifugal fan direct driven ( LG-90)1 x CMRT/2-3511 x Acoustic Box Fans (Inline) - CAB-355 RE1 x Twinflow STDL315-1EC1 x Mellizo XL EcoWatt 3000 - Twin Fan1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x CMT-2 250-100 2.2KW - LG270 Single inlet centrifugal fan direct driven1 x filter pack (set of 2) pt no. 4438891 x Topvex SF12 HWL. Supply AHU1 x Genius Whole house unit -1 x Villiavent VSR 300 Spare Motor1 x GENIOX 11 Roof Mounted External Unit1 x MTS10- extractor fan 3 step switch1 x ORKA HR D150 R8 MVHR unit1 x SAVE VTC 700 L Heat Recovery Unit1 x Spare filter for Energi Sava 200 & 250 HR unit1 x AKOR GD - Spare Motor1 x *VORT HRW 30 MONO Evo HCS - Single Room Heat Recovery Unit,