• Model:HR200WK

HR200WK single room heat recovery unit

£ 719.18 (excl. VAT)

£ 863.02 (inc. VAT)

A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x CAB-125 ECOWATT Energy Efficient Acoustic Box Fan1 x Ducting 45 Degree Bend - 500mm1 x Flat Roof Terminal -OFT 5 - Bitumen1 x JETLINE-315 - In Line Centrifugal Duct Fan1 x Differential Pressure Switch - 100 - 1000 Pa - IP651 x Speed Controller - REB11 x Ducting 90 Degree Bend - 800mm1 x Spiral Ducting 3 Meters - 800mm1 x Villiavent VTC 700 Spare Filter Set - F7/M5 Grade1 x 110 x 54mm Elbow Bend Male1 x Maxi Heat Recovery1 x Female Ducting Connector - 100mm1 x Duct Suspension Rings - 160mm1 x Synthetic Air Filter Media - 6mm x 1000mm x 1000mm1 x Synthetic Air Filter Media - 10mm x 2mtr x 20mtr Roll1 x Synthetic Air Filter Media - 6mm x 2mtr x 5mtr Roll1 x Synthetic Air Filter Media - 10mm x 2mtr x 10mtr Half Roll1 x 1mtr Insulated Round Ducting - 125mm1 x 1mtr Round Ducting - 125mm1 x 125mm Round 90 Degree Bend1 x Spiral Ducting 3 Meters - 500mm1 x MTP 10, 10K, Speed control1 x Anti Vibration Duct Suspension Rings - 300mm1 x JETLINE-100 ECOWATT - In Line Centrifugal Duct Fan1 x Spigot plate - 800mm1 x Spare filter for Energi Sava 200 & 250 HR unit1 x SAVE VTR 500 L Heat Recovery Unit1 x Villiavent VTC low Spare Filter Set1 x 110 x 54mm Horizontal 90 Degree Bend1 x ORKA HR D150 R8 MVHR unit1 x Spare filter Set for Energi Sava 300 & 400 HR unit1 x Villiavent VSR 300 Spare Motor1 x KVK Slim 100 - Low profile Semi Acoustic Box Fan1 x Slimline 150 High Efficiency, Low Profile Heat Recovery Unit1 x M5/G4 filter kit for IDEO HR unit1 x CADB/T-HE PRO-REG Series1 x SAVE VTC 700 L Heat Recovery Unit1 x AKOR Spare Filter1 x *VORT HRW 30 MONO Evo HCS WIFI - Single Room Heat Recovery Unit,1 x HR-500 DP Heat Exchange Unit1 x GEO Ground Source Heat Exchanger1 x GENIOX 11 Roof Mounted External Unit1 x Male Ducting Connector - 100mm1 x *VORT HRW 40 MONO Evo HCS WIFI - Single Room Heat Recovery Unit,1 x *VORT HRW 30 MONO Evo - Single Room Heat Recovery Unit,1 x filter pack (set of 2) pt no. 4438891 x Ancillary Sealing Band - 150mm1 x Ducting T Piece Equal - 150mm1 x AKOR GD - Spare Motor
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 10.53