A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x 100mm Round Connector with Damper1 x Spiral Ducting 1 meter - 400mm1 x Metal Inline Fan - VENT-250NK1 x Differential Pressure Switch - 200 - 1000 Pa - IP541 x Female Ducting Connector - 450mm1 x Soler & Palau - Contra Rotating TCBTx2-630 - IP651 x Elta Unpodded Silencer Melinex 1D-500mm1 x Circular Inline Silencers - 600mm - 600mm1 x Elta Unpodded Silencer 1D-500mm1 x Elta Unpodded Silencer 1D-250mm1 x Universal Pipe Fixing Clip1 x 100mm Round Equal T Piece1 x Etaline 250mm - D2 01 3 Phase1 x Lindab ILC 250 - Inline Tube Fan1 x Dektite Combo Pipe Flashing - DC210REC1 x KV 250 L Sileo1 x EKHR 280-2SW BCMI1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Female Ducting Connector - 150mm1 x Ducting 45 Degree Bend - 560mm1 x Etamaster EM 250 EC 02 (high Power) inline mix-vent fan1 x Duct Termination with Mesh - 560mm1 x KD 250 L1 Circular duct fan1 x Male Ducting Connector - 450mm1 x Elta Unpodded Silencer Melinex 1D-560mm1 x Elta Unpodded Silencer Melinex 1D-450mm1 x FSAF1000C1DA SILENCER 1070/161 x Elta Unpodded Silencer 1D-800mm1 x FSAF1000B1DB Silencer 1043/241 x FSAF1250C1DA Silencer 1320/201 x FSAF400B1DA Silencer 450/81 x ZAC- 350 -4-11 x M5/G4 filter kit for IDEO HR unit1 x HR200WK single room heat recovery unit1 x Spare filter Set for Energi Sava 300 & 400 HR unit1 x *VORT HRW 30 MONO Evo HCS - Single Room Heat Recovery Unit,1 x filter pack (set of 2) pt no. 4438891 x SAVE VSR 300 heat recovery unit1 x AKOR Mounting Plate for GD model(VIM166423)1 x Villiavent VTC low Spare Filter Set1 x Villiavent VTC 700 Spare Filter Set - F7/M5 Grade1 x AKOR T3/7 Spare Motor1 x F7/G4 filter kit for IDEO HR unit1 x Spare filter for Energi Sava 200 & 250 HR unit
Air Quality Sensor - AQS
Air Quality Sensor - AQS
£ 98.29 now £ 65.00
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...