• Model:HR200WK

HR200WK single room heat recovery unit

£ 719.18 (excl. VAT)

£ 863.02 (inc. VAT)

A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x JCA 560 - Back Draft Shutter for CRHB/CRHT Roof Fans3 x Ducting 45 Degree Bend - 355mm1 x Duct Termination with Mesh - 355mm1 x Ducting Reducers Short - 355mm-315mm1 x Spiral Duct Grille Termination - 355mm1 x Flanged Spigot - 355mm1 x Spigot plate - 355mm1 x Female Ducting Connector - 355mm1 x Duct Suspension Rings - 355mm2 x Ducting 90 Degree Bend - 355mm1 x Duct Fast Clamps - 355mm2 x Ducting Y Piece - 355mm1 x Purlin Box 400/450 for RAW Cowls1 x Transformer (silent) speed controller - RE 5.0 Amp1 x HV Wall Mounted Belt Drive Fan 1000mm 220V to 240V / 50Hz 0.75kW - Single Phase1 x CTHB/6-2501 x Helios HQW-250/2 - IP551 x Purlin Box 500/560 for RAW Cowls1 x JCC-560 - ADAPTER FOR CIRCULAR DUCT - for CTHB/T Roof Fans,1 x Inclined Kurb support for CTHB/6-4001 x Elta 3 Amp Electronic single phase speed controller with TK1 x Soler & Palau - HCBT/4-710/H - IP651 x HV Wall Mounted Belt Drive Fan 1500mm 220V to 240V / 50Hz 1.5kW - Single Phase1 x HCFT/4-400/H-BPN E20,P 0.25KW1 x HV Wall Mounted Belt Drive Fan 1000mm 400V / 50Hz 0.75kW - Three Phase1 x Elta Variable Speed Drive IP66 - 0.75KW1 x Purlin Box 630/710 for RAW Cowls1 x Direct Delivery Surcharge1 x Differential Pressure Switch - 20 - 300 Pa - IP541 x SG AW 1000 Guard 6-Pole1 x JAA-560 Acoustic Upstand1 x DV-ROF-V-225 Roof mounted unit1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-1000-B 5.5kw1 x HRB/2-250-AMPN1 x Elta EC Electronic Controller1 x Inline Hepa filter with housing & pre-filters1 x AW Sileo EC Plate Axial Fan - Three Phase - 1000mm1 x Soler & Palau - HCBT/4-800/H-B FLOW ( Supply Air Fan) - IP551 x Soler & Palau - HCBT/4-1000/H-X - IP551 x M5/G4 filter kit for IDEO HR unit1 x IDEO 325 Ecowatt1 x Soler & Palau HXM-300mm1 x Rosenberg DQ 1000-8 plate axial fan1 x Soler & Palau - HCBB/6-560/H - IP651 x Soler & Palau - HCBT/4-500/H - IP651 x DEF-800AN1 x Spiral end cap - 355mm1 x SAVE VTC 700 L Heat Recovery Unit
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 41.95