A heat recovery unit specifically designed for use in residential kitchens and utility rooms to meet the latest building regulations. The compact, self contained unit is designed for through wall mounting. The unit has a constant trickle ventilation boosted by a remote humidistat or a 3 speed controller. The compact, self contained unit is designed for through the wall mounting. An optional range of sensors are available.

The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air.This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Available in three speeds: 16, 30 and 61 l/s. Suitable for installation in a kitchen.

The unit is also suitable for light commercial requirements up to 61 l/s. Heat Exchanger
The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation.

The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming saturated with moisture. Energy is saved on room heating with no power being used by the cube itself.

The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room.

A wall extension sleeve is available.
Maintenance

Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. Quick release grilles give instant access to the integral washable filters. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.

Efficiency: The unit should retain between 65%-70% of the temperature differential of out going air.

Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.

Motor: should be a 3-speed 240V 50Hz A/C with sleeve bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a one shot thermal overload protective device.

Fan: The two polymeric fan impellers should be a centrifugal forward curved type, dynamically balanced mounted on a common shaft.

Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.

Filter: Should be a washable reticulated foam type coarse filter.

Construction: The unit outer case should be manufactured from brown powder coated sheet metal terminating in an external weather cowl.The internal grille should be white ABS.
PDF Files


HR200 WK

1 x Airvent ceiling fan controller2 x CBT-100N Centrifugal2 x 7 Day Programmable TIMECLOCK1 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR2 x CBB-60N Centrifugal1 x Vent Axia ACM 150 inline mixed flow duct fan2 x Systemair Save Connect 2.0 Internet Module1 x CBS-60 Outlet Flange for CSB/CBT-601 x REB-CVF 0-10v Controller1 x Transformer Speed Control - RTRE- 1.5Amp1 x CBA-60 Inlet Flange for CBT-601 x GENIOX 11 Internal Mounted Unit1 x TD160-NT Mixvent - 100mm - TD160 Timer1 x GENIOX 11 Roof Mounted External Unit1 x CS2 Current Switch1 x DDMP 10-08 3F 2210W M6A4 DG02 x Potentiometer EGH 01 - for DDMP Fans1 x CBM 9/7 4p 420W RE-VR1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt C VR1 x CBP-7/7-RC1 x DDMP 09/07 Mounting Flange1 x DDMP 12-12 3F 5700W M6M0 DG71 x ACOAS/ AC/EC Auto Changeover 8Amp1 x HIMF - Mixed Flow Fan 125mm Inline Fan2 x Envirovent 4 Way Remote Control Switch - SWHBKRF-41 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Multiflow SMB550/4-1AC1 x CBM 9-9 550w 4P VR (Open Motor)1 x RSK355 - Back Draught Shutter1 x Speed Controller - REB11 x DDMP 12-12 3F 1810W M6A4 DG01 x UB47- Universal Insulated Terminal1 x GXC6EC - High Performance Extract Fan1 x QPTW 250C Acoustic Twin Fan with Controller1 x Mini Diffuser - 100mm1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Contactor Interface Station - CI91 x Silentub - STUB 1001 x SAVE VSR 300 heat recovery unit1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x CO2 Room Sensor - CO2-R1 x ACO8AC/EC AutoChangeover panel1 x CBA-100 Inlet Flange for CBT-1001 x TUNE-R-160-3-M2 - Control Damper1 x 100mm Round Connector with Damper1 x VTR 500 STD Filter Kit1 x KBA- Inlet Mounting 2251 x Duct Termination with Mesh - 150mm1 x DDMP 10-10 1F 1000W M6A2 DA51 x CBT-80N Centrifugal1 x CBM 7/7 147w 4P RE-VR1 x CAD-COMPACT 900 ADVANCED N8 - MVHR unit