Kitchen Extract Grille with Grease Filter and External Wall Fan Kit complete AWV-15s Fan motor, CEF Ceiling Mounted Grease Filter and Speed Control

Direct drive externally mounted centrifugal fans, manufactured from high grade pressed galvanized steel protected against corrosion by polyester paint finish. All the fans are provided with a removable top for easy access to motor for cleaning or inspection, a large grille opening, a back-draft damper, a pre-wired terminal box and a backward curved centrifugal impeller.
All the motors are single-phase 230V - 50Hz, IP44, Class F, with ball bearings greased for life, and safety thermal overload protection of manual reset type.
AWV series models incorporate a powerful external rotor motor that has been factory matched to a nonoverloading backward curved centrifugal fan wheel. This powerful combination enables the AWV to deliver exceptional airflow performances against high static pressure typically found in ducted ventilation systems. All motors within the AWV series are fully speed controllable using voltage or frequency control regulators.

• Externally mounted
• Manufactured from high grade pressed galvanized steel, with baked enamel coating.
• Removable top for easy access to motor for cleaning or inspection.
• Large grille opening for easy passing of lint and other potentially clogging materials.
• Includes prewired terminal box.
Wheel/Impeller
• Backward curved centrifugal type.
• Factory matched to an external rotor motor and dynamically balanced to eliminate vibration.

Ceiling Mounted Egg Crate Grille with Removable Mesh Type Grease Filter for Kitchen Extraction - 280 x 185

Egg-crate grilles have a 13mm x 13mm square core and with their high free area are ideal for many applications, the egg crate grille with removable core has been fabricated to fit a commercial grade mesh type grease filter suitable for kitchen extraction. The egg crate grille with filter can be flush mounted into a wall / ceiling creating a very subtle and aesthetic extraction hood.

Comes with a metal plenum box with 150mm spigot for connection to remote extraxctor fan via ducting.

Mesh type filters are designed for use in commercial kitchens and ventilation from food preparation areas where their primary function is to reduce grease travelling from the cooking area up into the extract duct.

KIT CONTENT
CEF-280 - Concealed Grease Filter
AWV15s - Sidewall Fan 150mm
REB1-N - Speed Control
Semi-Flexible Duct - 150mm x 3 Mtr
Jubliee Clamps and Duct Tape

Available Options

Customers also purchased...

1 x Belt Drive Cased Axial Fan - 710mm - H version1 x Elta SLC710/4A-3AC - IP551 x Elta SLC710/4B-3AC - IP551 x CC-710-2.2kw1 x Soler & Palau TCBB/6-710/L - IP651 x Belt Drive Cased Axial Fan - 710mm - L version1 x Soler & Palau TCBT/4-710/L - IP651 x Soler & Palau TCBT/6-710/L - IP651 x Soler & Palau TCBT/4-710/H - IP651 x AL 710 D4 01 - High Performance Long Cased Axial Fan1 x Ducting 15 Degree Bend - 125mm1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Easy-fix termination kit - High Rise Ventilator - EFT1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Elta Wall Cowl SWC56/631 x Elta Variable Speed Drive IP66 - 2.2KW1 x Elta Wall Cowl SWC35/401 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC45/501 x GRA-100 External Grill by S&P1 x Elta Wall Cowl SWC25/311 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Elta Variable Speed Drive IP66 - 4.0KW1 x Jet Cowl - 315mm1 x D2E-146-AP47-751 x Small Centrifugal Fans CBM/2-133/190 185w1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW 1.5 Amp Transformer speed controller1 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Helios TSW 0.3Amp Compact Transformer speed controller2 x Vent Axia ACM 150 inline mixed flow duct fan2 x Helios TSW MCB Amp Transformer speed controller1 x RDS 7 Helios Transformer Controller With Motor Protection2 x Helios TSW 10 Amp Transformer speed controller1 x Systemair Save Connect 2.0 Internet Module1 x RTRD - Three Phase Speed Controller - 2 Amp1 x Vent Axia ACM 125 inline mixed flow duct fan1 x DEF-140T Inlet Guard for the CBT-100N2 x CS2 Current Switch1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Push Timer Switch - ZA42 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x MV-B Dual Switch for use with Helios HQW plate fans,1 x Isolator Switch - ISOSW1 x 7 Day Programmable TIMECLOCK1 x MWS 1.5 – Transformer Controller With Motor Protection1 x WS - Reversing Switch from Helios Fans1 x Helios HQW-200/2 - IP551 x Two Speed Switch - REGUL-21 x ERR 31/1 Centrifugal inline fan1 x Electronic extractor fan speed controller - FSC 1.52 x Helios HQW-630/4 - IP551 x Transformer (silent) speed controller - RE 3.0 Amp2 x CBS-60 Outlet Flange for CSB/CBT-601 x Remote Timer Control - 13511 x Helios HQW-200/4 - IP551 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Transformer 5 Speed Controller - ATC1-2TK1 x Airvent ceiling fan controller1 x Speed Controller - REB31 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Transformer 5 Speed Controller - ATC1-8TK1 x Skyflow SSR Horizontal Roof Cowl SSR31/35B2 x Speed Controller - REB52 x Vent Axia ACM 200 inline mixed flow duct fan1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Speed Controller - REB101 x Transformer Speed Control - RTRE- 5.0Amp2 x Multiflow SMB550/4-1AC1 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x Helios HQW-315/4 - IP55