Rosenberg Axial Fans are mostly used in Air heaters, Heat pumps, Condensers, Cooling units, Evaporators and Chillers. The fans are suitable for handling air and other non-aggressive gases or fumes.
More variants are possible on request (for ex. custom painting).
The motors are available as asynchronous external rotor motors or as electronically commutated (EC) external rotor motors.
The main concern for all axial fans was to keep noise emission low in the main range of application of the fan while having an optimal performance curve with the long and short nozzled inlet cone.
All the listed fans in this catalog correspond to the ErP 2015.
Fans are measured according to accuracy class 1 (DIN 24166). (AC types according to accuracy class 3)
Protection guard Serving as finger protection and depending on the construction type also for mounting the fan onto the inlet cone. If the protection guard is only for safety reasons, the motor supporting function is taken by the motor support.
Inlet cone:
A square inlet cone is installed as standard.
This can differ depending on the required construction type.
Air Performance Curves:
The air performance curves have been established using the intake test method in the test chamber as shown below according to DIN EN ISO 5801.
They show pressure increase as a function of the volume flow and are valid for air with a density of 1,2 kg/m³ with a temperature of t=20°C. Performance curves were recorded in installation type A (free flowing intake and exhaust). Testing conducted with optimal inlet cone and without protection guard.
Important note:
Power consumption of fans change linearly proportional to the density of conveyed air/gas.
Direction of air flow:
The respective available directions of air flow are displayed at the bottom of each fan type page marked with . Improper direction of rotation can overload the motor (not possible with EC motors integrated electronics) ; therefore it is essential to check the direction of rotation before initial operation.
According to the applications the air flow direction can differ. Thats why this information should be given with every request.

Customers also purchased...

1 x Spiral end cap - 250mm1 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Small Centrifugal Fans CBM/2-146/180-300 W1 x Elta Standard Ambient Flexible Connector - 315mm1 x EM 200-E2M 01- Etamaster-2001 x Soler & Palau TCBB/2-250/H - IP541 x Duct Fast Clamps - 200mm1 x Raptor SDA315/4-1AC1 x RD28S-4DW.4R.2L1 x Elta Standard Ambient Flexible Connector - 560mm1 x Rosenberg DRAD-224-4 Double Inlet High Efficiency Radial Fan1 x R2E 140-AF48-18 - EBM PAPST Impeller & Motor1 x Nicotra RDH E4-0450 (L)1 x Nicotra RDH E4-0560 (K)1 x High Temperature Flexible Connector - 063-0315-PU2501 x Woods 1400mm Flex Connector - 4148511 x Ziehl-Abegg - RH45C-ZIK.DC.CR (116190)1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Soler & Palau VFD-T inverter 5 amp IP541 x Nicotra RDH E4-0500 (K)1 x KAD-225-F400 Rectangle Flexible Connector1 x RD35S-4DW.6W.3L - 122297 (Three Phase)1 x Elta Standard Ambient Flexible Connector - 500mm1 x Purlin Box 800 for RAW Cowls1 x MTP 10, 10K, Speed control1 x Small Centrifugal Fan - CBM/4-160/150-125 W1 x RD31S-4EW.6Q.AL - 122296 (Single Phase)1 x Villavent VR 700 Belt - 1240mm1 x Elta Standard Ambient Flexible Connector - 630mm1 x Flanged Spigot - 150mm1 x Elta Standard Ambient Flexible Connector - 250mm1 x Acopel F400-900/1801 x Acopel F400-630/1601 x Hydor HPA630/6-1A1 x Rosenberg DQ 630-4 plate axial fan1 x HCFT/6-630mm plastic impeller plate fan1 x Helios HQW-630/6 - IP551 x HRT/6-630/35-BZ E111 x HCFB/4-630mm plastic impeller plate fan1 x Soler & Palau - HXTR/4-630/H - IP54