• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Versio Square Ceiling Diffusers - RS141 x Biflow SB315-CON4-3 - High Temperature Bifurcated Fan1 x Elta Cased Axial Flange - 710mm1 x Quietflow SQS100-1ECL - Centrifugal Box Fan1 x Envirovent Silent MV160/100S Mixvent - 100mm - (5 year warranty)1 x Singleflow SSDL100-1EC1 x Quietflow SQSDCV100-1ECL - Centrifugal Box Fan1 x KVK Slim 100 - Low profile Semi Acoustic Box Fan1 x KVK SLIM 100 EC - Centrifugal Circular Duct Fan1 x Sentinel D-BOX 100S1 x Acoustic Box Fans (Inline) - CAB-1001 x Acoustic MiniBox Fan - MINI-BOX 1001 x Elta 10 Amp Electronic single phase speed controller.1 x NKS-D swirl diffuser v-300 x 300mm1 x ELTA - Single Phase Transformer 2amps1 x Electronic extractor fan speed controller - FSC 1.51 x Circular Ceiling Diffuser - TST 1251 x Balance S Diffuser - NO RING - 125mm1 x Circular Ceiling Diffuser - TST 1001 x EC6H - Reversible Group Fan Electronic Controller1 x PCA Diffuser - PCA-3151 x Elta 2 Amp Electronic single phase speed controller.1 x Circular Ceiling Diffuser - TST 2001 x Curved Blade Grille 600x600 (2way blow)1 x EFSC-3N- Single Phase Speed Control1 x Elta 6 Amp Electronic single phase speed controller with TK1 x Circular Ceiling Diffuser - TST 1601 x ELTA - Single Phase Transformer 16amps1 x ELTA - Single Phase Transformer 8amps1 x Airvent ceiling fan controller1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x JSR 200 Painted RAL50181 x Round ceiling diffuser 400mm1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta 3 Amp Electronic single phase speed controller.1 x Round ceiling diffuser 300mm1 x Round ceiling diffuser 200mm1 x ELTA - Single Phase Transformer 4amps1 x Balance S Diffuser - NO RING - 100mm1 x AIRVENT speed control - AIR4019611 x COM-31 x Elta 6 Amp Electronic single phase speed controller.1 x EFSC-6N- Single Phase Speed Control1 x Round ceiling diffuser 250mm1 x ELTA - Single Phase Transformer 10amps1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Push Timer Switch - ZA41 x Helios ZNE Electronic Fan Overrun Timer1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x 7 Day Programmable TIMECLOCK1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x CONTROL ECOWATT - Basic1 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV1 x Elta ACO Panel 149-ACO18B1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Systemair Save Connect 2.0 Internet Module1 x EC-Vent Room Unit1 x Easy-fix termination kit - High Rise Ventilator - EFT1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Elta Louvre Shutter - 400mm1 x GRA-100 External Grill by S&P1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Trickle And Boost controller for use with the SLP EC Slimpak fans1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)