• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

2 x DS-2/2 2-Speed Switch IP54 (Single Phase)1 x Elta Qube SQU Centrifugal Box Fan - SQU4/4-3 HTS - Three Phase1 x Duct Fast Clamps - 125mm1 x Soler & Palau TCBT/6-630/L - IP651 x Compact SCD630/4-1AC1 x FU 075 04 Frequency Inverter (IP20)1 x Isolator Switch - ISOSW1 x Helios GigaBox 710mm GBD 710/4 centrifugal1 x ACO3TO-ADS-VFC-7.1A1 x HRU Controller1 x Acopel F400-900/1801 x Spigot plate - 125mm1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x FK 125 Fast Clamp1 x Duct Suspension Rings - 125mm1 x Spiral Ducting 1 meter - 125mm1 x Flanged Spigot - 125mm1 x Elta SLC630/4B-3AC - IP551 x Acopel F400-560/1601 x Belt Drive Cased Axial Fan - 630mm - H version1 x Spiral Duct Grille Termination - 125mm1 x Compact SCD630/4-3AC1 x FU 075 52 Frequency Inverter (IP20)2 x AMD-630/2 - High Performance Cased Axial Fan1 x Frequency converter RUCK - FU 075 201 x Raptor SDA630/4-1EC1 x Male Ducting Connector - 800mm1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x Acopel F400-250/1601 x Acopel F400-225/1601 x ELTA - Three Phase Transformer 10amps1 x Acopel F400-315/1601 x Acopel F400-120/1601 x Soler & Palau - Contra Rotating TCBTx2-630 - IP651 x Duct Termination with Mesh - 800mm1 x Elta Variable Speed Drive IP66 - 2.2KW1 x Acopel F400-800/1801 x AEL - Outlet Flexible Connection for TLZ450 R1 x Ducting 15 Degree Bend - 125mm1 x Soler & Palau TCBT/4-630/H - IP651 x FU 22 25 Frequency Inverter1 x FRQ5-10A Inverter Speed controller1 x Acopel F400-500/1601 x Raptor SDA630/46-3AC1 x Elta Variable Speed Drive IP66 - 5.5KW1 x ELTA - Three Phase Transformer 3amps1 x Helios TSD 5.5 Transformer Speed Control (400v)1 x Belt Drive Cased Axial Fan - 630mm - L version1 x ASSG/F 500-560 Flex. conn. DVG1 x Spigot plate - 800mm1 x Elta Standard Ambient Flexible Connector - 315mm1 x Ducting 90 Degree Bend - 125mm1 x FU 22 04 Frequency Inverter1 x Elta Turboflow-TF - 630mm - Three phase1 x Soler & Palau TCBB/6-630/L - IP651 x Frequency converter RUCK - FU 075 211 x Ducting Y Piece - 125mm1 x Soler & Palau TCBB/4-630/L - IP651 x Spiral Ducting 3 Meters - 125mm1 x FU 15 40 Frequency Inverter1 x Duct Quick Suspension Rings with Clasp - 125mm1 x FSAF500FTX 500 mounting feet (Pair)1 x *NEW* TD EVO-200 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan1 x Helios VARD 355/2/2-TK1 x Spiral Ducting 3 Meters - 630mm1 x Elta SCP560/4-1AC - IP551 x Blast Gate (Manual) 250mm1 x Roof Axial Cowl - RAW10001 x ACQ-150-12D Acoustic Inline Box Fan1 x ELS Plasterboard Adaptor1 x MUB 062 630D4 Multibox1 x Helios DDF-250 Roof Cowl1 x KV 250 L Sileo1 x EM 200-E2M 01- Etamaster-2001 x CO2 Room Sensor - CO2-R1 x CAB-160 ECOWATT Energy Efficient Acoustic Box Fan1 x Etamaster EM 250 EC 02 (high Power) inline mix-vent fan1 x Belt Drive Cased Axial Fan - 500mm - H version1 x Ducting 90 Degree Bend - 150mm1 x EM 315-E2M 01- Etamaster-315
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 10.53

Look good, works well, except the shaft of the lanellae cuts...