• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Belt Drive Cased Axial Fan - 560mm - H version1 x Elta Unpodded Silencer Melinex 2D-1000mm Dia1 x Belt Drive Cased Axial Fan - 800mm - G version1 x Biflow SB315-CON2-3 - High Temperature Bifurcated Fan1 x CBT-100N Centrifugal ATEX II 2G Exe II T31 x Belt Drive Cased Axial Fan - 710mm - H version1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT560/4-3AC1 x Acopel F400-225/1601 x Duct Split Rings (Pair) -560mm1 x 220x90mm Elbow Bend with 125mm Fixed Spigot1 x 220x90mm Flat Channel Connector1 x 220x90mm Mounting Clip (Individual)1 x 220x90mm Equal T Piece1 x 220x90mm x 2m Low Profile Plastic Ducting - 2 Meter1 x FSAF1000C1DA SILENCER 1070/161 x CBT-130N Centrifugal ATEX II 3D ExtD 125*C1 x Elta Unpodded Silencer 1D-560mm1 x Belt Drive Cased Axial Fan - 710mm - L version1 x AXC 315-6/11-2(B)-PV 300*C - Smoke Extract Fan1 x Elta Unpodded Silencer Melinex 1D-560mm1 x Belt Drive Cased Axial Fan - 500mm - L version1 x Belt Drive Cased Axial Fan - 900mm - H version1 x Belt Drive Cased Axial Fan - 800mm - L version1 x DKEX 315-4 Centrifugal High Performance ATEX Fan1 x FSAF1000B1DB Silencer 1043/241 x FSAF355B1DX Silencer 395/81 x Elta Podded Silencer 2D- 710mm1 x Belt Drive Cased Axial Fan - 800mm - H version1 x Belt Drive Cased Axial Fan - 450mm - L version1 x Belt Drive Cased Axial Fan - 450mm - H version1 x CBT-130N Centrifugal ATEX II 2G Exd IIB T41 x Belt Drive Cased Axial Fan - 630mm - L version1 x Elta Unpodded Silencer 1D-800mm1 x CBT-100 N (230/400V50HZ) LG270-EXDIIBT41 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan1 x KTEX 50-25-4 Fan (ATEX)1 x Circular Inline Silencers - 600mm - 600mm1 x AXCBF 800D4-18 IE2 Bifurcated Axial Fans1 x Belt Drive Cased Axial Fan - 630mm - H version1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 500mm1 x RVK-EX 315D4 (ATEX) - 315mm Atex Rated Centrifugal Fan1 x EX 140A-2 (Three Phase) Centrifugal Fan (ATEX)1 x FSAF315B2DX Silencer 355/81 x Elta Unpodded Silencer Melinex 1D-450mm
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...