400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Ducting Y Piece - 125mm1 x Ducting T Piece Equal - 125mm1 x Ducting 15 Degree Bend - 125mm1 x CC-710-2.2kw1 x Duct Termination with Mesh - 125mm1 x Ducting 45 Degree Bend - 630mm1 x Elta SLC710/4B-3AC - IP551 x Helios SB-250-C SilentBox Acoustic Inline Fan1 x Duct Quick Suspension Rings with Clasp - 125mm1 x Female Ducting Connector - 125mm1 x Plastic Kitchen Extractors - CK40F1 x KVK SLIM 250 EC - Centrifugal Circular Duct Fan1 x Flanged Spigot - 400mm1 x Woods 31JMV14/2/6/33 - Long Cased Axial Fan 315mm1 x Ducting Y Piece - 100mm1 x Soler & Palau - Contra Rotating TCBTx2-630 - IP651 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT350/4-3AC1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT450/4-3AC1 x Soler & Palau TCBT/6-630/H - IP651 x EM30-24 Electro-Mechanical Control Panel1 x EC-Vent control board1 x CVAT Acoustic Kitchen Fan & Inverter Kit - CVAT/4-6000/500 ND - Pack 62 x ACO-TK-ADS Auto Changeover Panel - Single Phase1 x Flanged Spigot - 100mm1 x CRHB/6- 630mm Roof mounted Fan - Horizontal discharge1 x Raptor SDA250/4-1AC1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-1000-A 5.5kw1 x Female Ducting Connector - 710mm1 x Access Door for Circular Duct - 400 x 300 - SIZE 631 x K 200 L Sileo1 x Access Door 400mm x 400mm1 x Access Door for Circular Duct - 250 x 150 - SIZE 251 x Access Door for Circular Duct - 300 x 200 - SIZE 501 x Duct Wrap Insulation - AWDW25mm1 x HD Series Control Damper - 2300mm X 1000mm1 x EQ641406 630mm Max Fan1 x HCFB/4-315mm plastic impeller plate fan1 x Ducting 90 Degree Bend - 100mm1 x Contra Rotating TCBBx2-630 Cased Axial - Single Phase - IP65 - Soler & Palau1 x CRHB-250N Ecowatt - Energy Efficient Roof Fan1 x Access Door for Circular Duct - 400 x 300 - SIZE 401 x Access Door for Circular Duct - 250 x 150 - SIZE 151 x Elta Wall Cowl SWC45/501 x Blast Gate (Manual) 250mm
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...