• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x 315mm EC TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 200mm EC TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 250mm EC TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 350mm EC TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 50 MAXFAN Compac - EJ513266 - 500mm Fan and Inverter Kit 1PH to 3PH1 x 40JM/16/2/5/32 - 2Pole - 3PH - Long Cased Axial Fan - EJ4312731 x 30JM.33.BIF.200D.2P.3PH.71WEG - High Temp Bifurcated Fan - 305mm1 x 50JM/20/2/6/16 - 2Pole - 1PH - Long Cased Axial Fan - EJ5312741 x 450mm EC (3PH) TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 25JM.33.BIF.200D.4P.3PH.63WEG - High Temp Bifurcated Fan - 250mm1 x 31 MAXFAN Compac - EJ313266 - 315mm Fan and Inverter Kit 1PH to 3PH1 x 50 SC MAXFAN Compac - EJ513255 - 500mm Fan and Inverter Kit 1PH to 3PH (Lower Power)1 x 150mm EC TWIN BOX FAN - WOODS Acoustic EC twin Fan1 x 45 MAXFAN Compac - EJ463266 - 450mm Fan and Inverter Kit 1PH to 3PH1 x 35 MAXFAN Compac - EJ353266 - 355mm Fan and Inverter Kit 1PH to 3PH1 x 40 MAXFAN Compac - EJ413456 - 400mm Fan and Inverter Kit 1PH to 3PH1 x 30JM.33.BIF.200D.4P.3PH.63WEG - High Temp Bifurcated Fan - 305mm1 x 25JM.33.BIF.200D.2P.3PH.71WEG - High Temp Bifurcated Fan - 250mm1 x Helios TSW 1.5 Amp Transformer speed controller1 x Time Delay Unit - DT20B1 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B1 x Elta Wall Cowl SWC56/631 x GRA-100 External Grill by S&P1 x Elta Wall Cowl SWC45/501 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC25/311 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Jet Cowl - 315mm1 x Helios DDF-200 Roof Cowl1 x Helios TSW MCB Amp Transformer speed controller1 x Remote Timer Control - 13511 x Helios TSW 10 Amp Transformer speed controller1 x Run On Timer - 5s - 4hrs - RT5A1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Elta ACO Panel 149-ACO14E1 x EM30-24 Electro-Mechanical Control Panel1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Speed Controller - REB3
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 44.99

Well made and robust, but it was not use for my application ...