• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x TD Mixvent 800/200 EEXEIIT31 x Purlin Box 800 for RAW Cowls1 x MV EC 100 Multivent1 x 204x60mm x 1m Low Profile Plastic Ducting - 1 Meter1 x TD Mixvent 1100/250 EEXEIIT31 x Ductwrap Insulation DW501 x JPA-1100 Accessory Adapter Plate1 x Soler & Palau TCBT/4-800/L - IP651 x JBS-1250 Flat Roof Upstand for HCTT/4-1000/B1 x Purlin Box 400/450 for RAW Cowls1 x Ducting T Piece Equal - 400mm1 x Flanged Spigot - 400mm1 x Elta SLC800/4A-3AC - IP551 x Helios HQW-500/4 - IP551 x Soler & Palau TCBT/6-800/H - IP651 x Duct Termination with Mesh - 400mm1 x JCC-560 - ADAPTER FOR CIRCULAR DUCT - for CTHB/T Roof Fans,1 x HRB/4-500-30-APNC1 x Helios HQW-500/6 - IP551 x Ducting Y Piece - 400mm1 x Spiral Ducting 3 Meters - 400mm1 x Duct Fast Clamps - 400mm1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x Purlin Box 300/315 for RAW Cowls1 x Elta SLC800/4B-3AC - IP551 x Belt Drive Cased Axial Fan - 800mm - H version1 x Anti Vibration Duct Suspension Rings - 400mm1 x HCFT/4-5001 x HCBT-4/500-H - Three Phase 400v Only - 56033228001 x Elta SPA500/4-3EC - IP541 x HRT/4-500/25-BPN C1 x Elta SCP500/4-3AC - IP551 x CC-800-5.5kw1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Mini Diffuser - 100mm1 x Inclined Curb support BI-3 for TH-5001 x Duct Wrap Insulation - AWDW25mm1 x Ducting 90 Degree Bend - 400mm1 x Purlin Box 200/250 for RAW Cowls1 x Elta SPA500/6-1AC - IP541 x HRB/4-500-25-BPN1 x Purlin Box 500/560 for RAW Cowls1 x Elta SLC500-1EC -IE5 Motor- IP551 x 204x60mm Elbow Bend with 100mm Fixed Spigot1 x 204x60mm Elbow Bend with 150mm Fixed Spigot1 x HRT/4-400-BPN1 x HCFT/4-400/H-BPN E20,P 0.25KW1 x Elta 2 Amp Electronic single phase speed controller.1 x 204x60mm 45 Degree Horizontal Bend1 x TTC-2000 Three phase electric heater controller1 x EMF 500-14 - ECO MIXED FLOW IN-LINE FANS1 x Elta SCP315/4-3AC - IP551 x Soler & Palau - HCBB/2-315/H - IP651 x CONTROL ECOWATT - Basic1 x Nicotra Direct Delivery Surcharge1 x R.O.I Customs Charge for Pallet Deliveries1 x Soler & Palau - HXTR/2-250/H - IP44
Air Quality Sensor - AQS
Air Quality Sensor - AQS
£ 98.29 now £ 65.00
Reviews
Vectaire Elegance Low Energy DMEV Fan Range
Vectaire Elegance Low Energy DMEV Fan Range
£ 119.00

I've had 2 of these fans for 4 years now, and they are great...