• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Spiral Ducting 3 Meters - 710mm1 x Spiral Ducting 3 Meters - 560mm1 x Air Quality Sensor - AQS1 x Belt Drive Cased Axial Fan - 900mm - H version1 x Bifurcated Fan - TET 6/6001 x Differential Pressure Switch - 20 - 300 Pa - IP541 x CK-60F Kit1 x Acoustic Box Fans (Inline) - CAB-250N1 x Euro Series - Plate Axial - ESP500141 x KD 315 L1 - High Performance Duct Fan1 x Helios GigaBox 315mm GBW 315/4 centrifugal1 x Round ceiling diffuser 350mm1 x Etaline Max-Fan - 315mm - E2 011 x Flat Roof Terminal -OFT 1 - Felt & Asphalt 110mm1 x Belt Drive Cased Axial Fan - 560mm - L version1 x Elta SLC500/4A-3AC - IP551 x BD-10/08 M4-0.59kw Centrifugal1 x EBB-175 T DESIGN Centrifugal Extractor Fan1 x Plastic Kitchen Extractors - CK40F1 x HXP500/4-1 - 4 Pole - Single Phase1 x Elta SLC500/4B-1AC - IP551 x CBP-DC 18/181 x MFQ450-14 - SQUARE MIXED FLOW FAN - 450mm Single Phase1 x Differential Pressure Switch - 50 - 500 Pa - IP541 x Compact SCD500/4-3AC1 x Helios GigaBox 450mm GBD 450/4/4 centrifugal1 x Lindab ILC 250 - Inline Tube Fan1 x "VX100" - Standard Bathroom Axial fan - 100mm1 x CBT-130N Centrifugal1 x Spiral end cap - 80mm1 x CBPx2-9/7-D1 x Elta SCP400/4-3AC - IP551 x CBT-80N Centrifugal1 x Singleflow SSDL250-1EC1 x HCFT/4-400mm plastic impeller plate fan1 x Decor 200-C Bathroom Fan1 x HRB/4-500-35-BPNC1 x Kitchen Extract Grille with Grease Filter and External Wall Fan1 x AXCBF 800D4-18 IE2 Bifurcated Axial Fans1 x ARIETT I - Centrifugal Bathroom Fan1 x HRT/4-450/35-BPN1 x Hydor Typhoon Circulation Fans - HVFB - 300mm1 x Raptor SDA500/46-3AC1 x HRT/4-500/30-BPN1 x Soler & Palau TCBT/4-630/L - IP651 x Raptor SDA630/6-1AC1 x FlameProof Plate Axial Fan - Single Phase - 12 inches - Eexd IIC T4 -4pole1 x FlameProof Plate Axial Fan - Single Phase - 15 inches - Eexd IIC T4 -4pole1 x AL 500 D2 01 AXIALINE - High Performance Long Cased Axial Fan1 x AW Sileo EC Plate Axial Fan - Three Phase - 710mm1 x EC Trickle and boost module - IP561 x DKEX 355-6 Centrifugal High Performance ATEX Fan1 x CVAT/4-4000/400 ND 0.37Kw (230/400V50HZ) EXDIIBHT4 - ATEX RATED CABINET FAN
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...