• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Elta Variable Speed Drive IP66 - 2.2KW1 x Elta Variable Speed Drive IP66 - 7.5KW1 x FU 15 40 Frequency Inverter1 x FRQ5-4A V2 Inverter Speed Controller1 x FRQ-10A V2 Inverter Speed controller1 x Helios TSD 3.0 Transformer Speed Control (400v)1 x FU 075 52 Frequency Inverter (IP20)1 x FU 22 25 Frequency Inverter1 x Balance S Diffuser - NO RING - 125mm1 x Round ceiling diffuser 200mm1 x Elta 3 Amp Electronic single phase speed controller with TK2 x Remote Timer Control - 13511 x Helios ZNE Electronic Fan Overrun Timer1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x EM30-24 Electro-Mechanical Control Panel1 x REB-CVF 0-10v Controller1 x EC-Vent Room Unit1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B1 x EM30-24 Control Panel Commissioning Service1 x Elta Wall Cowl SWC56/631 x Elta Wall Cowl SWC35/401 x GRA-100 External Grill by S&P1 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC45/501 x Elta Wall Cowl SWC25/311 x Economy Airvent 100mm Fan with Timer1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x Economy Airvent 150mm Fan With Pullcord & Shutters1 x Duct Termination with Mesh - 450mm1 x DV-ROF-V-225 Roof mounted unit1 x Manrose 150mm - XF150BP1 x HIMF - Mixed Flow Fan 125mm Inline Fan1 x AL 315 EC 01 AXIALINE - High Performance Long Cased Axial Fan1 x AW Sileo EC Plate Axial Fan - Three Phase - 800mm1 x Maico EN31- Wall Mounted Fan1 x Manrose Auto Shutter - XF150AP1 x Fresh Air control carbon filter - 125mm1 x Capacitor 2uf for use with the EBM A4E range1 x AW Sileo EC Plate Axial Fan - Three Phase - 1000mm1 x LF-ME04F071LC3AC1 x CAB-315 ECOWATT Energy Efficient Acoustic Box Fan1 x Jetflow-HIT Metal inline - 125mm1 x CAB-355 ECOWATT Energy Efficient Acoustic Box Fan1 x AW Sileo EC Plate Axial Fan - Three Phase - 630mm1 x Small Centrifugal Fans CBM/2-133/190 185w1 x H14 Hepa Portable Air Purifier - PAP 350 CA H14 with Carbon Filter1 x CRBB/3-190/060M EC 1HO MP - External Rotor Motor Radial Fans1 x CAB-400 ECOWATT Energy Efficient Acoustic Box Fan1 x CRBB/3-160/052M EC 1H0 MP - Radial Impeller - 160mm1 x CAB-250 ECOWATT Energy Efficient Acoustic Box Fan1 x AW Sileo EC Plate Axial Fan - Three Phase - 710mm1 x Multi Input Run On Timer - 0 - 20min - CFCU2 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Elta 10 Amp Electronic single phase speed controller.1 x Elta Variable Speed Drive IP66 - 4.0KW1 x Circular Ceiling Diffuser - TST 1251 x ELTA - Three Phase Transformer 3amps1 x FU 075 04 Frequency Inverter (IP20)1 x Circular Ceiling Diffuser - TST 2001 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x MWS 5 – Transformer Controller With Motor Protection Unit1 x EC6H - Reversible Group Fan Electronic Controller1 x Round ceiling diffuser 300mm1 x Round ceiling diffuser 350mm1 x Three Phase Transformer controllers - RMT 1.5 Amp1 x EFSC-3N- Single Phase Speed Control1 x Airvent ceiling fan controller1 x COM-31 x PCA Diffuser - PCA-2501 x Elta 6 Amp Electronic single phase speed controller.1 x Run On Timer - 5s - 4hrs - RT5A1 x DEF-140T Inlet Guard for the CBT-100N1 x Push Timer Switch - ZA41 x Time Delay Unit - DT20B1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x 7 Day Programmable TIMECLOCK1 x Vent Axia T-Series Controller1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Electronic extractor fan speed controller - FSC 1.51 x TG-K3/NTC10-01 - Duct temperature sensor1 x Speed Controller - REB1-N1 x Transformer Speed Control - RTRE- 5.0Amp1 x CBM 9-9 550w 4P VR (Open Motor)1 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x Speed Controller - REB11 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x MTP 10, 10K, Speed control1 x Elta Variable Speed Drive IP66 - 0.75KW
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...