• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x VLTM102 5.5kW 11.7A IP66 (400V)2 x JSR 200 Painted RAL50181 x CBP-10/81 x FU 22 25 Frequency Inverter1 x FRQ-10A V2 Inverter Speed controller1 x Helios TSD 3.0 Transformer Speed Control (400v)1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x Circular Ceiling Diffuser - TST 1251 x FU 075 04 Frequency Inverter (IP20)1 x Frequency converter RUCK - FU 075 211 x FU 22 04 Frequency Inverter1 x ELTA - Three Phase Transformer 3amps1 x ELTA - Three Phase Transformer 10amps1 x NKS-D swirl diffuser v-300 x 300mm1 x Elta 10 Amp Electronic single phase speed controller.1 x FU 15 16 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Frequency converter RUCK - FU 075 201 x Elta Variable Speed Drive IP66 - 0.75KW1 x FU 075 52 Frequency Inverter (IP20)1 x Curved Blade Grille 600x600 (2way blow)1 x Round ceiling diffuser 400mm1 x ELTA - Single Phase Transformer 2amps1 x Circular Ceiling Diffuser - TST 2001 x Balance S Diffuser - NO RING - 125mm1 x PCA Diffuser - PCA-3151 x Round ceiling diffuser 200mm1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Balance S Diffuser - NO RING - 100mm1 x EC6H - Reversible Group Fan Electronic Controller1 x Circular Ceiling Diffuser - TST 1601 x Electronic extractor fan speed controller - FSC 1.51 x AIRVENT speed control - AIR4019611 x ELTA - Single Phase Transformer 12amps1 x Round ceiling diffuser 350mm1 x Airvent ceiling fan controller1 x Elta 3 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 8amps1 x ELTA - Single Phase Transformer 16amps1 x Round ceiling diffuser 300mm1 x Elta 3 Amp Electronic single phase speed controller with TK1 x EFSC-3N- Single Phase Speed Control1 x Elta 2 Amp Electronic single phase speed controller.1 x Elta 6 Amp Electronic single phase speed controller.1 x EFSC-6N- Single Phase Speed Control1 x PCA Diffuser - PCA-2501 x COM-31 x Remote Timer Control - 13511 x ELTA - Single Phase Transformer 10amps1 x Run On Timer - 5s - 4hrs - RT5A1 x Time Delay Unit - DT20B1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Push Timer Switch - ZA41 x 7 Day Programmable TIMECLOCK1 x Speed Controller - REB51 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x CONTROL ECOWATT - Basic1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Easy-fix termination kit - High Rise Ventilator - EFT1 x EC-Vent Room Unit1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B
BD9/9 centrifugal M4 0.35Kw
BD9/9 centrifugal M4 0.35Kw
£ 399.00 now £ 350.00
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 58.40

I have a loft mount extractor fan which was very noisy. I ...